摘要 通过对330MW机组开停机系统的现状调查,指出了存在的主要技术问题,并对滑参数停机、调停状态确认、冷态开机等进行了研究,提出了滑参数停机、调停机组节能、开机前准备、冷态开机的技术方案.该程序系统运行良好,机组开停机经济、规范、有序. Through the investigation of the current situation of the start shutdown auxiliary system of the 330MW generator unit,the main technical problems have been detected.By analyzing the sliding parameter shutdown of the unit,the confirmation of the state of the unit mediation and the cold starting,the paper puts forward the technical scheme of the sliding parameter shutdown of the unit,the energy saving of the generator unit, the preparation before the starting up and the cold starting.The system works well,and the start shutdown management system of the generator unit is more economical,standard and orderly.