摘要 结合烟气连续排放监测系统(CEMS)在某催化裂解装置(DCC)再生烟气净化项目中的应用,介绍烟气直接抽取法CEMS的系统构成,各监测元件的工作原理和相关配置,以及在工程设计选型和施工安装中需要注意的相关问题。 Through considering CEMS application in the regeneration flue gas purification in DCC unit,the composition of CEMS which adopts direct extraction technology for flue gas was introduced,including the working principle of each monitoring component and their configuration,as well as the issues concerning instruments selection and their installation during the process of design.
作者 李明建 LI Ming-jian(Huludao Design Institute of CNPC Northeast Petrochemical Engineering Co.,Ltd)
出处 《化工自动化及仪表》 CAS 2018年第9期676-679,共4页 Control and Instruments in Chemical Industry
关键词 CEMS DCC装置 监测点 SCR 非再生湿法脱硫除尘 取样管线 分析小屋 逆流式洗涤器 CEMS DCC unit monitoring point SCR non-renewable wet desulfurization and dust removal,sampling pipeline analyzer house reverse-flow scrubber
  • 相关文献

参考文献2

二级参考文献13

  • 1戴丽萍,赵云格.CEMS在火电厂中的应用[J].中国仪器仪表,2007(5):62-64. 被引量:6
  • 2王森,符青灵.仪表工试题集在线仪表分册[M].2版.北京:化学工业出版社,2008.
  • 3王森,朱炳兴.仪表工试题集(下册)[M].北京:化学工业出版社,1992.
  • 4闫维平,刘忠,王春波,等.电站燃煤锅炉石灰石烟气脱硫装置运行与控制[M].北京:中国电力出版社,2005.
  • 5孙克勤,钟秦.火电厂烟硫系统设计、建造及运行[M].北京:化学工业出版社,2005.
  • 6中国环境监测站,上海市环境监测中心,国家环保总局信息中心.HJ/T76-2007固定污染源烟气排放连续监测系统技术要求及检测方法(试行)[S].北京:中国环境科学出版社,2007.
  • 7上海市环境监测中心,中国环境监测总站,中日友好环境保护中心.HUT75-2007固定污染源烟气排放连续监测技术规范(试行)[S].北京:中国环境科学出版社,2007.
  • 8国家环境保护总局科技标准司.GB13271-2001锅炉大气污染物排放标准[S].北京:中国环境出版社,2001.
  • 9周根来.湿法烟气脱硫仪表选型及安装注意事项[J].石油化工自动化,2008,44(2):56-58. 被引量:6
  • 10肖瑞岗.CEMS在应用中存在的问题及解决办法[J].电力技术,2009(9):62-64. 被引量:7

共引文献7

同被引文献4

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部