隔膜加药泵不打压故障分析处理

Failure analysis and treatment of diaphragm dosing pump
下载PDF
导出
摘要 为了解决某新建大型化肥生产装置锅炉水系统隔膜加药泵不打压故障,对泵体检修过程中发现的问题进行逐一分析,最终找到了引起加药泵不打压的故障原因,并针对性地采取相应处理措施,消除了加药泵运行故障。 In order to solve the failure of diaphragm charging pump in the boiler water system of a new large fertilizer production plant, the problems found in the process of physical examination and repair of the pump were analyzed one by one.And the failure cause of the pump was finally found,and corresponding treatment measures were taken to eliminate the failure of the charging pump.
作者 杨林 YANG Lin(PetroChina Ningxia Pe troche mic al Comp any,Yinchuan Ningxia 750026,China)
出处 《石油化工应用》 CAS 2018年第9期118-120,共3页 Petrochemical Industry Application
关键词 隔膜加药泵 隔膜 过滤器 补油阀 diaphragm charge pump the diaphragm the filter fill oil valve
  • 相关文献

参考文献2

二级参考文献2

  • 1[美国]I J卡拉西克.泵手册[M].北京:机械工业出版社,1983..
  • 2[联邦德国]赫尔姆特·舒尔茨.泵原理、计算与结构[M].北京:机械工业出版社,1991..