摘要
CEFR是中国首座快中子实验反应堆,常规岛回路承担了将核岛热能转换为电能的重要功能,凝结水精处理系统的良好运行对净化和稳定常规岛的水质具有重要作用。本文通过对CEFR常规岛精处理系统运行中出现的问题,进行了缺陷的根本原因分析,以及对水质数据进行分析,总结得出导致精处理系统异常缺陷的根本原因,并且进行了应对措施的研究及系统整改。
CEFR is the first experimental fast neutron reactor of China,It has now been achieved full power and ran stably for 72 hours.The conventional island,where converting thermal energy into electricity is an important part in CEFR. The good operation of condensate fine treatment system is very important to maintenance the purity and quality of the water in CEFR' s conventional island. This paper analyzes the defect in the fine treatment system of conventional island and the water quality data, summarizes the root cause of the defects in the fine treatment system and researches the countermeasures and its implementation.
作者
吴自强
WU Zi-qiang(Division of Reactor Engineering Technology Research,Studio of China Experimental Fast Reactor Operation,Beijing 100000,China)
出处
《科技视界》
2018年第23期66-67,共2页
Science & Technology Vision
关键词
精处理系统
精密过滤器
滤芯
应对措施
Condensate polishing system
Ultra-filter
Filter element
Solutions