期刊文献+

超声洗脱-离子选择电极法测定工作场所空气中氟化物方法的改进 被引量:2

Improvement of determination of fluoride in workplace air by ultrasonic elution ion selective electrode method
下载PDF
导出
摘要 对工作场所空气中氟及其化合物的测定方法进行了研究,对现行GBZ/T 160.36标准中试样洗脱方法进行了改进,提出用超声振荡洗脱处理样品,用离子选择电极法测定样品中氟化物的含量。该法操作简单、准确快捷,测定结果令人满意。 the determination of fluorine and its compounds in the air of the workplace was studied.The method ofsample elution in the current GBZ/T 160.36 standard was improved.The sample was treated by ultrasonic oscillation elution,and the content of fluoride in the sample was determined by ion selective electrode method.The method is simple, accurateand quick, and the resuh is satisfactory.
作者 李建玲 冯锦仙 吕双荣 Li Jianling;Feng Jinxian;Lv Shuangrong(Yunnan Chemical Research Institute,Kunming 650041,China;Yunnan plus Safety Inspection Co.,Ltd.,Kunming 650106,China)
出处 《云南化工》 CAS 2018年第8期91-92,共2页 Yunnan Chemical Technology
关键词 工作场所 离子选择电极法 氟化物 workplace ion selective electrode method fluoride
  • 相关文献

参考文献1

二级参考文献5

  • 1夏克立.磷肥生产中的氟回收[J].磷肥与复肥,2005,20(5):60-64. 被引量:12
  • 2姜泉观,纪云晶,常元勋.环境化学毒物防治手册[M].北京:化学工业出版社.2004:79-87.
  • 3汪大翚,徐新华,赵伟荣.化工环境工程概论[M].北京:化学工业出版社,1992:219.
  • 4Andrzej K, Bozena R, Marek M. Silieareeovery from waste obtained in hydrofluoric acid and aluminum fluoride production from fluosilicie acid[J].Journal of Hazardous Materials, 1996,48:31 - 35.
  • 5李株.白炭黑应用的新领域[J].当代化工,2001,30(2):114-116. 被引量:24

共引文献4