为了解决化肥生产企业合成车间重要设备激冷水泵振动增大故障,采用故障排查法对泵体检修过程中发现的问题进行逐一分析,最终找到了引起激冷水泵振动故障原因,并针对性地采取相应处理措施,消除了泵体振动大的故障,并对其他可能导致激冷水泵振动大的原因和处理措施进行了分析。
To solve the equipment failure that the increased vibration of the chilling water pump, a troubleshooting methodology is used to analyze the problems during the process of pump body maintenance. Finally the vibration failure cause of the chilling water pump was found out and effective treatment measures were implemented. At the same time, the paper introduces the causes and treatment measures of vibration in chilling water pump.
作者
杨林
张一静
YANG Lin;ZHANG Yijing(PetroChina Ningxia Petrochemical Company,Yinchuan 750026,China;Ningxia Hengxin Jietong Information Technology Services Co.,Ltd.,Yinchuan 750011,China)
出处
《宁夏工程技术》
CAS
2018年第3期267-269,共3页
Ningxia Engineering Technology
关键词
激冷水泵
振动
联轴器
对中
定位止口
quench water pump
vibration
coupling
centring
locating check mouth