期刊文献+

时差式超声波流量计改进方法研究 被引量:2

Research on Improved Method of Time Difference Ultrasonic Flowmeter
下载PDF
导出
摘要 为提高流量测量准确度,在传统时差法流量测量理论的基础上,研究并实现了一种倒差式超声波流量测量方法。将温度、超声波速度以及液体流速给测量结果带来的影响进行了分析,从根本上减少了流量测量结果的影响因素,并提出了改进方法。通过实验验证了改进措施的可行性及准确度。实验数据表明,对影响因素进行误差补偿后,流量测量结果的准确度和稳定性明显提高。 In order to improve the accuracy of flowmeasurement,based on the traditional time-difference flowmeasurement theory,a fallback ultrasonic flowmeasurement method was studied and implemented. The influence of temperature,ultrasonic speed,and liquid flowrate on the measurement results was analyzed,fundamentally reducing the influencing factors of flowmeasurement results,an improved method was proposed. The experiment verifies the feasibility and accuracy of the improved measures. The experimental data shows that the accuracy and stability of the flowmeasurement result are significantly improved after error compensation of the influencing factors.
作者 王玉琢 王洪源 陈慕羿 王连峻 WANG Yuzhuo;WANG Hongyuan;CHEN Muyi;WANG Lianjun(Shenyang Ligong University,Shenyang 110159,China)
出处 《沈阳理工大学学报》 CAS 2018年第3期22-27,32,共7页 Journal of Shenyang Ligong University
关键词 超声波 流量测量 误差 ultrasonic flow measurement error
  • 相关文献

参考文献12

二级参考文献72

共引文献80

同被引文献4

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部