某斜向交汇预应力型钢混凝土梁-钢管混凝土柱节点研究 被引量:2

Research on the Joint of a Prestressed Steel Reinforced Concrete Beam and Concrete Filled Steel Tubular Column
下载PDF
导出
摘要 结合某大型铁路旅客站房高架候车厅楼盖结构,采用ADINA有限元软件及HyperMesh网格划分功能对楼盖结构复杂的斜向交汇预应力型钢混凝土梁-钢管混凝土柱节点进行数值分析,分析结果表明:该节点具有很好的承载力和刚度,各受力单元间具有良好的协同工作性能,同时为缩尺模型试验提供必要的数据支撑。采用1∶4缩尺模型试验,对节点在低周往复荷载下的力学性能进行研究,试验结果表明:该节点的滞回曲线饱满,具有良好的耗能能力,可实现"强节点强柱弱梁"的抗震设计要求。 Combined with a large passenger railway station elevated waiting hall floor structure,the finite element software ADINA and HyperMesh grid partition function are employed to analyze the complicated joint of the prestressed steelreinforced concrete beam and concrete filled steel tubular column based on numerical analysis. The results show that the joint has good bearing capacity,stiffness and cooperative work performance,which provide necessary data support for the following scale model test. The mechanical properties of the joint under low cycle reciprocating load are studied with 1 ∶ 4 scale model test. The test results show that the hysteretic curve of the joint is full with good energy dissipation capacity and can achieve the seismic design requirements of strong joint,strong column and weak beam.
作者 孙建龙 SUN Jian-long(China Railway First Survey and Design Institute Group Co.,Ltd.,Xi'an 710043,China)
出处 《铁道标准设计》 北大核心 2018年第10期147-151,共5页 Railway Standard Design
基金 中国铁道建筑总公司科技研发课题(合同编号:07-50C)
关键词 铁路客站 预应力型钢混凝土梁 钢管混凝土柱 数值分析 协同工作 耗能能力 Passenger railway station Prestressed steel reinforced concrete beams Concrete filled steeltubular column Numerical analysis Collaborative work Energy dissipation capacity
  • 相关文献

参考文献13

二级参考文献112

共引文献128

同被引文献18

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部