期刊文献+

基于AFE4490的无创血氧检测系统设计 被引量:2

Design of non-invasive blood oxygen detection system based on AFE4490
下载PDF
导出
摘要 文章以STM32F103VET6作为核心处理器,结合TI公司高性能集成血氧采集芯片AFE4490。硬件设计方面,简化了电路设计、降低功耗、缩小了电路尺寸。通过Fluke Index 2血氧模拟仪采集大量数据进行分析预处理,在滤波方面采用基于小波软(硬)阈值去除噪声方法,取得了不错的效果。利用无创检测血氧饱和度原理计算得到SpO2的百分比。 This article uses STM32F103VET6 as the core processor, combined with TI’s high-performance integrated blood oxygen acquisition chip AFE4490. Hardware design simplifes circuit design, reduces power consumption, and reduces circuit size. The Fluke Index 2 blood oxygen simulator collects a large amount of data for analysis and pretreatment, and uses fltering based on wavelet soft(hard)threshold to remove noise, and has achieved good results.The percentage of SpO2 calculated by using the principle of noninvasive measurement of blood oxygen saturation.
作者 张纯青 千博 Zhang Chunqing;Qian Bo(School of Mechanical and Electrical Engineering,Xidian University,Xi'an 710071,China)
出处 《无线互联科技》 2018年第19期157-158,共2页 Wireless Internet Technology
基金 超高速电路设计与电磁兼容教育部重点实验室开放式基金 项目名称:基于医疗感知的军事物联网 项目编号:2017KFKTB11
关键词 无创血氧测量 AFE4490 小波阈值 SPO2 noninvasive oximetry AFE4490 wavelet threshold SpO2
  • 相关文献

参考文献3

二级参考文献17

  • 1霍戌文,李伟,李进,陈科.光电探测微信号放大器设计[J].浙江理工大学学报(自然科学版),2005,22(3):259-262. 被引量:36
  • 2严新忠,杨静,郭略.人体血氧饱和度监测方法的研究[J].医疗装备,2005,18(12):1-4. 被引量:41
  • 3Nellcor technical stuff.A technology overview of the Nellcor Oximax pulse oximetry system[R/OL].[2009-10-01], http:// www.nellcor.com/ Catalog/PDF/Product/OxiMaxTechNote. pdf.
  • 4Nellcor technical stuff. Pulse Oximetry[EB/OL]. [2009-10- 01 ] .http://respiratorysolutions. covidien, corn/ PatientMonitoring/OxiMaxPulseOximetry/Monitors/ OxiMaxN600xPulseOximeter/tabid/73/Default.aspx.
  • 5http://www.ti.com/product/afe4490?keyMatch=AFE4490&tisearch =Search-EN-Everything.
  • 6http://www.ti.com/product/MS P430F6659?keyMatch=M SP430F66 59&tisearch=Search-EN-Everything.
  • 7Tavakoli M, Turicchia L, Sarpeshkar R. An ultra-low-power pulse oximeter implemented with an energy-efficient transimpedance amplifier[J]. IEEE Trans Biomed Circuit Syst, 2010, 4(1): 27-38.
  • 8Ye S, Zhou F, Chen H, et al. Non-lnvasive Method and Experimental Study for Measurement of Oxygen Saturation Rate in Wide Range[C]. IEEE ICBBE, 2008: 733-736.
  • 9Nitzan M, Taitelbaum H. The measurement of oxygen saturation in arterial and venous blood[J]. IEEE Instrument Measur Mag, 2008, 11(3): 9-15.
  • 10Reddy K A, George B, Mohan N M, et al. A novel calibration-free method of measurement of oxygen saturation in arterial blood[J]. IEEE Instrument Measur Mag, 2009, 58(5): 1699-1705.