期刊文献+

小剂量舒芬太尼预防剖宫产术中寒战和牵拉疼痛的效果观察 被引量:21

Observation of the effect of low-dose sufentanil as anesthetic in chills and traumatic pain during cesarean section
下载PDF
导出
摘要 目的探讨小剂量舒芬太尼作为麻醉剂应用于剖宫产术中防寒战和牵拉疼痛的效果。方法选取广饶县人民医院妇产科接收的剖宫产产妇92例,将产妇采用随机数字表法均分为两组,均行腰硬联合阻滞麻醉。观察组采用舒芬太尼(5μg)+0.75%罗哌卡因(1.5 m L)+10%葡萄糖(2.5 m L);对照组采用0.75%罗哌卡因(1.5 m L)+10%葡萄糖(2.5 m L)。统计记录两组产妇手术前、注药1、3、5、10 min以及手术结束产妇平均动脉压及心率水平,寒战、牵拉痛评分,手术时间、踝关节运动恢复时间和不同时间点的最大感觉阻滞平面。结果两组麻醉前和麻醉后各时间点的平均动脉压和心率水平差异无统计学意义(P>0.05);观察组注药后各时段的寒战和牵拉疼痛评分低于对照组(P<0.05);两组手术时间、踝关节运动恢复时间和最大感觉阻滞平面,新生儿出生后1 min、5 min Apgar评分,差异无统计学意义(P>0.05)。结论小剂量舒芬太尼作为麻醉剂应用于剖宫产术中防寒战和牵拉疼痛的效果显著,在临床中可推广使用。 Objective To explore the effect of low-dose sufentanil as an anesthetic in preventing chills and traction pain during cesarean section. Methods 98 cases of cesarean section were collected from obstetrics and gynecology in our hospital,and puerperae were randomly divided into two groups. All underwent lumbar and fast combined anesthesia. The study group used sufentanil( 5 μg) + 0. 75%ropivacaine( 1. 5 mL) + 10% glucose( 2. 5 mL). The control group was treated with 0. 75% ropivacaine( 1. 5 mL) + 10% glucose( 2. 5 mL). The mean arterial pressure and heart rate level,chills,operation time,recovery time of ankle joint movement and the maximum sensory block at different time points were recorded before and after the operation. Results There was no significant difference in the mean arterial pressure and heart rate between the two groups before and after anesthesia( P〈0. 05). The scores of chills and traction pain in the study group were significantly lower than those in the control group( P〈0. 05). The difference of operative time,the recovery time of the ankle joint movement and the maximum sensory block plane at different time points,Apgar score at 1 minute and5 min after birth between the two groups was not statistically significant( P〈0. 05). Conclusion Low dose of sufentanil is used as an anesthetic in the prevention of chills and traumatic pain during cesarean section. It is widely used in clinical practice.
作者 徐砚华 张丽珺 XU Yanhua;ZHANG Lijun(Department of Anesthesiology,Guangrao People's Hospital,Guangrao,Shandong 257300,China)
出处 《安徽医药》 CAS 2018年第11期2237-2240,共4页 Anhui Medical and Pharmaceutical Journal
关键词 舒芬太尼 剖宫产 寒战 牵拉疼痛 Sufentanil Cesarean section Cold stand Stretch pain
  • 相关文献

参考文献4

二级参考文献39

  • 1Sarma V, Fry EN. Doxapram after general anaesthesia. Its role in stopping shivering during recovery[J]. Anaesthesia,1991,46(6):460-461.
  • 2Alfonsi P. Postanaesthetic shivering. Epidemiology, patho- physiology and approaches to prevention and management[J]. Minerva Anestesiol,2003,69(5) :438-442.
  • 3Joris JL,Jacob EA, Sessler DI, et al. Spinal mechanisms contribute to analgesia produced by epidural sufentanil combined with bupivacaine for postoperative analgesia [J]. Anesth Analg,2003,97(5) :1446-1451.
  • 4Power I, Brown DT, Wildsmith JA. The effect of fenta- nyl,meperidine and diamorphine on nerve conduction in vitro[J]. Reg Anesth,1991,16(4) :204-208.
  • 5Polley LS, Columb MO,Wagner DS, et al. Dose-dependent reduction of the minimum local analgesic concentration of bupivaeaine by sufentanit for epidural analgesia in labor [J]. Anesthesiology, 1998,89(3) :626-632.
  • 6Leslie K,Sessler DI. Reduction in the shivering threshold is proportional to spinal block height[J]. Anesthesiology, 1996,84(6) :1327-1331.
  • 7Fuhrmann L, Ostergaard HT, Ostergaard D. Teaching Epidural for Labor Analgesia 23 [ J ]. Epidural Labor Analgesia: Childbirth Without Pain,2015,2 (4) : 303.
  • 8Ginosar Y, Birnbach DJ, Shirov TF, et al. Duration of Analgesia and Pruritus After Intrathecal Fentanyl for Labor Analgesia: No Significant Effect of A118G Ix - Opioid Receptor Polymorphism but a Marked Effect of Ethnically Distinct Hospital Populations [ J ]. Survey of Anesthesiology,2014,58 ( 3 ) : 124 - 125.
  • 9Chen SY, Lin PL, Yang YH, et al. The effects of different epidural analgesia formulas on labor and mode of delivery in nulliparous women [J].Taiwan Residents Journal of Obstetrics and Gynecology, 2014,53(1) :8 -11.
  • 10Hu LQ, Zhang J, Wong CA, et al. Impact of the introduction of neuraxial labor analgesia on mode of delivery at an urban maternity hospital in China [ J ]. International Journal of Gynecology & Ob- stetrics ,2015,129 ( 1 ) : 17 - 21.

共引文献163

同被引文献194

引证文献21

二级引证文献86

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;