摘要
利用电渗试验装置,进行阳极区添加氢氧化钠电渗加固与纯电渗加固软黏土地基的室内模型试验对比研究。试验过程中记录排水量、电流等指标,试验结束后检测土体抗剪强度、含水率。试验结果表明:阳极区添加氢氧化钠电渗加固软黏土地基比单独电渗作用下加固软黏土地基处理效果好;减缓阳极腐蚀,延长阳极使用寿命,可为工程应用提供借鉴。
We conducted a comparative experimental study about adding sodium hydroxide in anodic zone and electro-osmosis alone tests on the soft clay using a electro-osmosis apparatus. We recorded the volume of drainage and the current in the process of test, and measured the vane shear strength and moisture content after the test. The results show that the treatment effect of adding sodium hydroxide in anodic zone is better than that of electro-osmosis alone, it can slow down the anodic corrosion and prolong the service life of the anode, which can provide reference for engineering application.
作者
金锦强
袁国辉
章迪康
符洪涛
林海志
海钧
JIN Jin-qiang;YUAN Guo-hui;ZHANG Di-kang;FU Hong-tao;LIN Hai-zhi;HAI Jun(Wenzhou Oufei Development and Construction Investment Group Limited,Wenzhou,Zhejiang 325000,China;Collegeof Architecture and Civil Engineering,Wenzhou University,Wenzhou,Zhejiang 325035,China;Zhejiang Key Laboratory ofEngineering and Technology for Soft Rock Foundation and Tideland Reclamation,Wenzhou,Zhejiang 325035,China;Zhejiang Provincial Innovation Center of Tideland Reclamation and Ecological Protection,Wenzhou,Zhejiang 325035,China;Zhejiang Industry and Trade Polytechnic,Wenzhou,Zhejiang 325035,China;Dongtou County ZhuangyuanSouth Area Reclamation Construction and Development Co.,Ltd.,Wenzhou,Zhejiang 325035,China)
出处
《中国港湾建设》
2018年第9期29-34,共6页
China Harbour Engineering
基金
浙江省自然科学基金一般项目(LY17E080010)
温州市科技项目(S20170006
S20150030
S20160001)
关键词
电渗
氢氧化钠
软基处理
electro-osmosis
sodium hydroxide
ground treatment