通过综合分析由水泵、尾水换热器、隔膜式气压罐、机组冷却设备组成的循环技术供水系统,结合HLG2技术供水系统设计实例,提出了几种尾水换热器的布置及起吊方式,以满足不同型式水电站对循环技术供水的实际需求。
Design of the circulating technical water supply system in HLG2 Hydropower Station is introduced, which is composed of the water pump, tail water heat exchanger, diaphragm pressure tank and unit cooling device. Specifically, the arrangements and lifting schemes of several different types of the tail water heat exchanger for different hydropower stations are discussed.
作者
时志能
SHI Zhineng(Datang Hydropower Science and Technology Research Institute,Nanning 530025,China)
出处
《水电与新能源》
2018年第10期58-60,共3页
Hydropower and New Energy
关键词
循环冷却供水
尾水换热器
起吊方式
隔膜式气压罐
circulating cooling water supply
tail water heat exchanger
lifting method
diaphragm pressure tank