摘要
针对我国2013年实施的新版GB 50156—2012《汽车加油加气站设计与施工规范》的相关规定及"水十条"对水资源和土壤保护的要求,目前双层柴汽油罐在加油站设计中已开始广泛应用。从双层储罐的种类、监测手段、耐蚀性、使用寿命等方面,重点对SF和FF双层罐比对,阐述了双层FRP油罐的性能优势,为加油站的储罐建设及改造提供设计依据。
In view of relevant provisions of the new version of code for design and construction of automobile refueling and gas station implemented in 2013 in China and the requirements of "water ten" on water resources and soil protection, double-deck diesel fuel tank has been widely used in gas station design. This paper focuses on the comparison between SF and FF double layer tanks in terms of types, monitoring means, corrosion resistance and service life of double layer tanks, and expounds the performance advantages of double layer FRP tanks(FF), providing design basis for the storage tank construction and transformation of gas station
出处
《石油石化节能》
2018年第10期32-34,10,共3页
Energy Conservation in Petroleum & PetroChemical Industry
关键词
加油站
双层罐
环境保护
fuel filling station
double deck oil tank
environmental protection