摘要
介绍了佛山某商务中心综合楼空调系统的设计。为倡导绿色建筑的设计理念,空调系统设计采用冷凝热回收技术、转轮热回收机组、板管蒸发式冷凝全热回收新风空调热泵机组、冷凝水回收等一系列节能措施,大大提高了系统能效比,降低了空调能耗,节能效果显著。
Outlines the air conditioning system design of a commercial center building in Foshan. The design concept for green architecture,condensing heat recovery technology,runner heat recovery unit,plate pipe evaporation type condensation heat recovery fresh air heat pump unit,condensate recovery and a series of energy saving measures is adopted in the design of air conditioning system,greatly improving the energy efficiency ratio of the system,reduce the energy consumption of air conditioning,the energy saving effect is remarkable.
作者
刘坡军
许国强
LIU Pojun;XU Guoqiang(Architectural Design and Research Institute of Guangdong Province,Guangzhou 510010;JianKe Architectual Design Institute of Guandong Province CO.LTD,Guangzhou 510500)
出处
《制冷》
2018年第2期47-51,共5页
Refrigeration
关键词
冷热源
气流组织
热回收
节能
Heating & cooling source
Space air
diffusion
Heat recovery
Energy-saving