特高压变电站主变压器隔震装置安装技术研究 被引量:3

Research on Installation Technology of Main Transformer Shock Isolation Device in UHV Substation
下载PDF
导出
摘要 选址在可能会发生强震地方的特高压变电站,由于在电网中的重要地位需要主设备满足抗强震的要求。特高压变电站大型变压器为了提高变压器自身的抗震能力,采用了新型设备隔震装置。此文结合工程实际应用系统,阐述了特高压变电站大型变压器的隔震装置安装技术。 If a UHV substation is located in some place where strong earthquake may occur, the main equipment shall meet the requirement of strong shock-resistance due to the important position in power grid. New shock isolation device has been adopted to enhance the capability of large transformer in UHV substation. Combining with the practical application system, this paper has elaborated the installation technology of shock isolation device for large transformer in UHV substation.
作者 张卫东 张廷 ZHANG Weidong;ZHANG Ting(State Grid Shandong Electric Power Company,Jinan 250001,China)
出处 《国网技术学院学报》 2018年第5期32-34,共3页 Journal of State Grid Technology College
关键词 特高压 变压器 隔震装置 安装技术 UHV transformer shock isolation device installation technology
  • 相关文献

参考文献3

二级参考文献13

  • 1邱法维,欧进萍.输电塔-线耦联体系地震反应分析方法(Ⅱ):纵向[J].地震工程与工程振动,1996,16(4):78-87. 被引量:5
  • 2GB50011-2001,建筑抗震设计规范(2008年版)[S].
  • 3张提波 唐家祥.主动基础减震结构随机最优控制系统和电流变体阻尼嚣设计.工程抗震,2007,(1):30-32.
  • 4李江,何玉敖.减震和半主动控制组成的结构振动混合控制体系分析[J].第十届全国结构工程会议论文集,2001,(3):13-17.
  • 5[2]Irvine H M,Gaughey T K.The linear theory of free vibrations of a suspended cable[J].Proc.R.Soc.Lond,1974,(A 341):299-315.
  • 6电力土建专业网.汶川大地震中电网供电设施受到严重破坏[EB/OL].(2008-11-05)[2010-06-08].http://www.ncpe.com.cn/tjzyw/tjgcscd/cd080302.htm.
  • 7JGI18-2000建筑隔震橡胶支座[S].
  • 8CECS126-2001,叠层橡胶支座隔震技术规程[S].
  • 9GB50260-96 电力设施抗震设计规范.
  • 10周世平.5.12汶川大地震变压器损坏情况分析[J].湖北电力,2008,32(4):1-4. 被引量:18