摘要
采用过硫酸钾氧化法和硝酸-高氯酸氧化法对标准样品和工业废水中的总磷含量进行了测定,并对测定结果和工作曲线进行了对比。结果表明:过硫酸钾氧化法操作安全简便,准确度和精密度更高;硝酸-高氯酸氧化法检测结果偏低。
K2S2O8 digestion method and HNO3-HCI04 digestion method have been used to test the content of total phosphorus in standard samples and industrial waste water. By comparing the test results and working curves,the result shows that: K2S2O8 digestion method is safety and simple,with a higher degree of accuracy. The test results of K2S2O8 digestion method are lower than the test results of HNO3-HClO4 digestion method.
作者
顾奇龙
章金龙
魏辉荣
胡志文
陈华
赵鑫伟
GU Qi-long;ZHANG Jin-long;WEI Hui-rong;HU Zhi-wen;CHEN Hua;ZHAO Xin-wei(Zhejiang A mino-chem Co.,Ltd.,Shaoxing,Zhejiang 312300,China)
出处
《浙江化工》
CAS
2018年第10期47-49,54,共4页
Zhejiang Chemical Industry
关键词
工业废水
总磷
过硫酸钾氧化法
硝酸-高氯酸氧化法
industrial waste water
total phosphorus
K2S208 digestion method
HNO3-HCl04 digestion