期刊文献+

A rapid and convenient experimental method of absolutely calibrating transmission of x-ray flat-response filter

A rapid and convenient experimental method of absolutely calibrating transmission of x-ray flat-response filter
下载PDF
导出
摘要 We develop a rapid and convenient experimental method of absolutely calibrating the transmission of an x-ray flatresponse filter. The calibration experiment is performed on a small laser-target facility, and a set of high resolution holographic flat-field grating spectrometers is used as a discrimination system of the laser-produced x-ray source. Given that the holographic flat-field grating has a relatively large width, the grating is divided into two regions for use in that direction,where one region has the filter added and the other region does not. The filter transmission is determined by dividing the x-ray signal counts detected when the filter is in the line of sight by those detected when the filter is out of the line of sight.We find that the calibration results of this experiment agree with the calibration results using a synchrotron radiation source,as well as simulation results. Our method is not only highly reliable but also rapid and convenient. We develop a rapid and convenient experimental method of absolutely calibrating the transmission of an x-ray flatresponse filter. The calibration experiment is performed on a small laser-target facility, and a set of high resolution holographic flat-field grating spectrometers is used as a discrimination system of the laser-produced x-ray source. Given that the holographic flat-field grating has a relatively large width, the grating is divided into two regions for use in that direction,where one region has the filter added and the other region does not. The filter transmission is determined by dividing the x-ray signal counts detected when the filter is in the line of sight by those detected when the filter is out of the line of sight.We find that the calibration results of this experiment agree with the calibration results using a synchrotron radiation source,as well as simulation results. Our method is not only highly reliable but also rapid and convenient.
作者 Jian Yu Li-Fei Hou Jing Wang Wen-Hai Zhang Ming Chen Bao-Chong Zhou Sha-Li Xiao Shen-Ye Liu 余建;候立飞;王静;张文海;陈铭;周保充;肖沙里;刘慎业(Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province,College of Optoelectronic Engineering,Shenzhen University;Research Center of Laser Fusion,China Academy of Engineering Physics;College of Optoelectronic Engineering,Chongqing University)
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第10期271-275,共5页 中国物理B(英文版)
基金 Project supported by the National Natural Science Foundation of China(Grant Nos.11405158 and 11775203) the Presidential Foundation of China Academy of Engineering Physics(Grant No.YZJJLX 2016007)
关键词 flat-response filter absolute transmission flat-field grating spectrometer x-ray CCD camera flat-response filter absolute transmission flat-field grating spectrometer x-ray CCD camera
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部