近年来,我国的区域供冷系统在城市住宅小区中得以广泛应用。大多数系统存在选型偏大的现象,初投资浪费、系统运行效率低,造成能源的浪费。因此,准确预测区域建筑的冷负荷是应用区域供冷系统亟待解决关键问题之一。现在常用域供冷设计中常采用负荷模拟算法均对人行为做了简化处理,不能全面反映不同用户由于人行为造成的负荷差异性,可能造成系统负荷的不合理估计。为了探究人行为对于住宅小区尖峰负荷、总负荷等方面的影响程度,本文基于实测和问卷调研数据对武汉市某住宅小区建立DeST模型并展开模拟,对比了采用详细的人行为模型与全时间全空间模型、固定作息模型的模拟结果,及实测结果的冷负荷差异,结果表明过于简化的人行为模型会造成系统尖峰负荷和总负荷的过大估计,考虑人行为差异的模型更贴近实际测试结果。本研究也对此方法在住宅小区冷负荷模拟应用展开了探讨。
District cooling systems are widely used in urban residential communities in China. Most of such systems are oversized, which leads to wasted investment, low operational efficiency and, thus, a waste of energy. The accurate prediction of district cooling loads that can support the rightsizing of cooling plant equipment remains a challenge. This study develops a novel stochastic modeling method that consists of six prototype house models representing most apartments in a district, occupant behavior models of residential buildings reflecting their spatial and temporal diversity as well as their complexity based on a large-scale residential survey in China, and a stochastic sampling process to represent all apartments and occupants in the district. The stochastic method was applied to a case study using the Designer's Simulation Toolkit(DeST) to simulate the cooling loads of a residential district in Wuhan, China, results of which show that the simulation results agreed well with the measured data.
作者
安晶晶
燕达
洪天真
孙开宇
AN Jingjing;YAN Da;HONG Tianzhen;SUN Kaiyu(Building Energy Research Center,Tsinghua University,Beijing 100084,China;Building Technology and Urban Systems Division,Lawrence Berkeley National Laboratory,Berkeley,USA)
出处
《建筑科学》
CSCD
北大核心
2018年第10期18-25,共8页
Building Science
基金
"十三五"国家重点研发计划课题"建筑全性能联合仿真平台内核开发"(2017YFC0702204)
关键词
人行为
住宅小区负荷
DeST
冷负荷
设备选型
occupant behavior
district cooling load
DeST
cooling load
equipment sizing