摘要
变压器的稳定运行是保证产线生产的关键,在加强变压器的维护管理、定期做预防性试验的同时,引进了局部放电检测设备和技术,通过局部放电检测来判断变压器内部的局部放电隐患,弥补了变压器运行诊断技术的缺失,也为变压器的维修提供技术支持。
The stable operation of the transformer is the key to ensure pi^oduction line . While strengthening the maintenance and management of the transformer and doing the preventive test regularly, the partial discharge detection equipment and the partial discharge detection technology were introduced. Through the partial discharge detection is used to judge the hidden trouble in the partial discharge in the transformer, which makes up for the lack of the transformer operation diagnosis technology and provides technical support for the maintenance of the transformer.
作者
原辉
邵永生
Yuan Hui;Shao Yongsheng(Rizhao Iron & Steel Co.,Ltd.,Rizhao 27680)
出处
《冶金设备》
2018年第A01期142-143,154,共3页
Metallurgical Equipment
关键词
变压器
局部放电
检测
Transformer
Partial discharge
Testing