摘要
针对某型号用波纹管型自调式节流制冷器的调节器进行结构分析,确定波纹管是结构中在振动条件下的薄弱环节。在不牺牲制冷器性能的前提下对其两端进行限位设计,提高其抗振能力。利用有限元分析软件进行力学仿真分析,最后通过试验验证,证明优化设计后的节流制冷器在抗振方面有了很大的提高。
Based on the structure analysis of self - regulated J - T coolers with bellows, it was determined that the bellows were the vulnerable spot during the vibration. Without sacrificing the performance of J - T coolers, the design of structure which both ends of bellow were fixed or supported improved the vibration resistance of J - T coolers. It was proved to be effective by the optimized structure simulation analysis and the product verification test.
作者
徐庆松
聂雪莲
龚志红
Xu Qingsong;Nie Xuelian;Gong Zhihong(The 11th Research Institute of China Electronics Technology Group Corporation,Beijing 100015,China;The Military Representative Office of the Air Force in North China,Beijing 100086,China)
出处
《低温与超导》
CAS
北大核心
2018年第10期25-28,共4页
Cryogenics and Superconductivity
关键词
调节器
波纹管
膜片弹簧
力学分析
Regulator
Bellow
Diaphragm spring
Mechanical analysis