期刊文献+

微库仑法测定污泥中可吸附有机卤化物(AOX)

Determination of adsorbable organic halogens(AOX) in sludge samples by microcoulometry
下载PDF
导出
摘要 建立了一种污泥样品中可吸附有机卤化物的测定方法。通过HNO_3-NaNO_3-活性炭体系震荡提取污泥中的有机卤化物,采用微库仑法测定AOX含量。结果表明,该法精密度和准确度较好,加标回收率达到95.6%,精密度RSD2.1%~3.1%。本法是测定污泥样品中可吸附有机卤化物的高效方法。 A method for determination of adsorbable organic halogens (AOX) in sludge samples was established. Organic halogens in sludge samples were shocked and extracted by nitric acid-sodium nitrate-activated carbon, and the halogens were determined by microcoulometry. Results showed that accuracy and precision of this method were good. the recovery ratio amount to 95.6% and the RSD range from 2.1% to 3.1%. this method for determination of AOX in sludge samples is efficent.
作者 王东 孙国娟 王越慜 WANG Dong;SUN Guo-juan;WANG Yue-min(Xuancheng Environmental Monitoring Center,Xuaneheng 242000,China;Anhui province National Copper Lead,Zinc and Product Quality Supervision and Inspection Center,Tongling 244000,China;Jena Analytical Instruments Co.,Ltd.,Beijing 100027,China)
出处 《化学工程师》 CAS 2018年第10期31-33,共3页 Chemical Engineer
关键词 微库仑法 可吸附有机卤化物 污泥 Microeoulometry AOX sludge
  • 相关文献

参考文献8

二级参考文献67

  • 1宫东杰,苏希.饮用水中可吸附有机卤化物的测定[J].中国卫生工程学,2000(2):30-32. 被引量:2
  • 2赵英,白晓琴,张颖,顾平.序批式膜生物反应器处理生活污水的特性[J].化工学报,2005,56(11):2195-2199. 被引量:4
  • 3胡雄星,张文英,韩中豪,王文华.水样中可吸附有机卤化物(AOX)的测定[J].中国环境监测,2006,22(3):15-17. 被引量:20
  • 4R. J. Kavlock, G. P. Daston, C. DeRosa, et al . Research Needs for the Risk Assessment of Health and Environmental Effects of Endocrine Disruptors. A Report of the U. S. EPA-sponsored Workshop [ J ]. Environ Health Perspoct. 1996,104(Suppl4) :715.
  • 5K. L. Willett,E. M. Ulich R. A. Hites . Diffrental toxicity and Environmental Fates of Hexachlorocyclohexane Isomers [ J ].Environmental Science and Technology. 1998, 32 ( 15 ) :2197.
  • 6C. S. Bottaro,J. W. Kiceniuk,A. Chatt. Spatial Distribution of Extractable Organohalogens in Northern Pink Shrimp in the North Atlantik[ J ]. BiologicalTrace Element Research. 1998,71(1):149.
  • 7C. Molina, G. Durand and D. Barcelo. Trace determination of herbicides in estuarine waters by liquid chromatography-high-flow pneumatically assisted electrospray mass spectrometry[ J]. Journal of Chromatography A. 1995,712( 1 ) : 113.
  • 8S. Chiron, J. A. Tones, A. Fernandez-Alba. Identification of Carbofuran and Methiocarb and Their Transformation Products in Estuarine Water by On-line Solid Phase Exreaction Liquid Chromatography-Mass Spectrometry [ J ]. Intern. J.Environ. Anal. Chem. 1996,65:37.
  • 9L. H. Keith, M. M. Walker. Handbook of Air Toxics, Sampiing Analysis and Properties [ M ]. CRC Lewis Publishers,1995.
  • 10T. Kuechler, H. Brzeinski. Application of GC-MS/MS for the analysis of PCDD/Fs in sewage effluents [ J ]. Chemosphere.2000,40(2) :213.

共引文献55

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部