期刊文献+

Influence of the Right Ventricular Lead Location on Ventricular Arrhythmias in Cardiac Resynchronization Therapy 被引量:1

Influence of the Right Ventricular Lead Location on Ventricular Arrhythmias in Cardiac Resynchronization Therapy
原文传递
导出
摘要 Background: The influence of different right ventricular lead locations on ventricular arrhythmias (VTA) in patients with a cardiac resynchronization therapy (CRT) is not clear. This study aimed to evaluate the influence on VTA in patients with a CRT when right ventricular lead was positioned at the right ventricular middle septum (RVMS) and the right ventricular apical (RVA). Methods: A total of 352 patients implanted with a CRT-defibrillator (CRT-D) between May 2012 and July 2016 in the Department of Cardiology of Anhui Provincial Hospital were included. Two-year clinical and pacemaker follow-up data were collected to evaluate the influence of the right ventricular lead location on VTA. Patients were divided into the RVMS group (n = 155) and the RVA group (n = 197) based on the right ventricular lead position. The VTA were compared between these two groups using a Kaplan-Meier curve and Cox multivariate analysis. Results: When the left ventricular lead location was not considered, RVMS and RVA locations did not affect VTA. However, the subgroup analysis results showed that when the left ventricular lead was positioned at the anterolateral cardiac vein (ALCV), the RVMS group had an increased risk ofventricular arrhythmias and appropriate defibrillation (hazard ratio [HR] - 3.29, P = 0.01 and HR = 4.33, P 〈 0.01, respectively); when the left ventricular lead was at the posterolateral cardiac vein (PLCV), these risks in the RVMS group decreased (HR = 0.45, P = 0.02 and HR = 0.33, P 〈 0.01, respectively), and when the lett ventricular lead was at the lateral cardiac vein, there was no difference between the two groups. In regard to inappropriate defibrillation, there was no significant difference among all these groups. Conclusions: When the left ventricular lead was positioned at ALCV or PLCV, the right ventricular lead location was associated with VTA and appropriate defibrillation after CRT. Greater distances between leads not only improved cardiac function but also may reduce the risk of VTA. Background: The influence of different right ventricular lead locations on ventricular arrhythmias (VTA) in patients with a cardiac resynchronization therapy (CRT) is not clear. This study aimed to evaluate the influence on VTA in patients with a CRT when right ventricular lead was positioned at the right ventricular middle septum (RVMS) and the right ventricular apical (RVA). Methods: A total of 352 patients implanted with a CRT-defibrillator (CRT-D) between May 2012 and July 2016 in the Department of Cardiology of Anhui Provincial Hospital were included. Two-year clinical and pacemaker follow-up data were collected to evaluate the influence of the right ventricular lead location on VTA. Patients were divided into the RVMS group (n = 155) and the RVA group (n = 197) based on the right ventricular lead position. The VTA were compared between these two groups using a Kaplan-Meier curve and Cox multivariate analysis. Results: When the left ventricular lead location was not considered, RVMS and RVA locations did not affect VTA. However, the subgroup analysis results showed that when the left ventricular lead was positioned at the anterolateral cardiac vein (ALCV), the RVMS group had an increased risk ofventricular arrhythmias and appropriate defibrillation (hazard ratio [HR] - 3.29, P = 0.01 and HR = 4.33, P 〈 0.01, respectively); when the left ventricular lead was at the posterolateral cardiac vein (PLCV), these risks in the RVMS group decreased (HR = 0.45, P = 0.02 and HR = 0.33, P 〈 0.01, respectively), and when the lett ventricular lead was at the lateral cardiac vein, there was no difference between the two groups. In regard to inappropriate defibrillation, there was no significant difference among all these groups. Conclusions: When the left ventricular lead was positioned at ALCV or PLCV, the right ventricular lead location was associated with VTA and appropriate defibrillation after CRT. Greater distances between leads not only improved cardiac function but also may reduce the risk of VTA.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2018年第20期2402-2409,共8页 中华医学杂志(英文版)
关键词 Cardiac Resynchronization Therapy Heart Failure Ventricular Remodeling Ventricular Arrhythmias Cardiac Resynchronization Therapy Heart Failure Ventricular Remodeling Ventricular Arrhythmias
  • 相关文献

同被引文献1

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部