摘要
文章提出了在不使用电平振荡器和标准零电平表校准选频电平表平衡输入电平测量准确度的新方法,对给出的新方法进行了不确定度评定,并将此方法应用于国家计量技术规范《选频电平表校准规范》中。
In this paper, a new method to calibrate the accuracy of thebalanced input level measurement of a selective level meter withoutusing level oscillator and standard zero level meter is proposed, and theuncertainty of the new method is evaluated, The new method will beapplied to the latest national metrological technical standard CalibrationSpecification of Selection level Meter.
作者
陆福敏
詹志强
Lu Fumin;Zhan Zhiqiang(Shanghai Institute of Measurement and TestingTechnolog)
出处
《上海计量测试》
2018年第5期2-5,共4页
Shanghai Measurement and Testing
关键词
选频电平表
校准
电平振荡器
数字多用表
衰减器
selective level meter
calibration
level oscillator
digitalmultimeter
attenuator