摘要 用激光粒度仪测试三种抹茶样品的粒度,对加分散剂和不加分散剂进行测试结果的比较,并通过改变循环泵转速和分散时间来寻求最佳测试条件。结果表明,抹茶样品不加分散剂在超声条件下也有良好的分散效果,得到稳定的测试结果。循环泵转速在1600 rpm、分散时间1 min为最佳测试条件。此外,用该测试方法可以得出在0.100~1000μm范围内各区域的样品累积百分数、不同粒径点对应的累积百分含量,以及不同筛目所对应的粒径大小及其分布累积情况。 The particle sizes of three maeeha samples were measured by laser particle sizer. Comparison was made between results of maeeha samples with and without dispersant. Meanwhile, the best test conditions were tound by changing the rotational speed of circulating pump and dispersing time. The results showed that the samples had good dispersing effeet without dispersant under ultrasonic condition, and stable test results were gained. Moreover, 1600 μm of circulating pump rotational speed and 1 min of dispersion time was considered to be the best test condition. In addition, this method could be used to obtain the cumulative percentage of samples, the cumulative percentage of ditterent particle sizes, and the particle size together with the distribution accumulation corresponding to ditterent sieves in the range of 0.100~1000μm.
作者 王瑾 刘相真 周卫龙 徐建峰 WANG Jin;LIU Xiang-zhen;ZHOU Wei-long;XU Jian-feng(Hangzhou Tea Research Institute,CHINA COOP,Hangzhou 310016,China;China National Center of Quality Supervision and Inspection of Tea,Hangzhou 310016,China;Zhejiang Key Laboratory of Transboundary Applied Technology for Tea Resources,Hangzhou 310016,China)
出处 《中国茶叶加工》 2018年第3期35-41,共7页 China Tea Processing
基金 "十三五"国家重点研发计划课题(2017YFD0400804)
关键词 激光粒度仪 抹茶 粒径 Laser particle sizer Maccha Particle size
  • 相关文献

参考文献9

二级参考文献90

共引文献111

同被引文献39

引证文献4

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部