期刊文献+

Reduced graphene oxide-nano zero value iron(rGO-nZVI) micro-electrolysis accelerating Cr(Ⅵ) removal in aquifer 被引量:12

Reduced graphene oxide-nano zero value iron(rGO-nZVI) micro-electrolysis accelerating Cr(Ⅵ) removal in aquifer
原文传递
导出
摘要 Nanoscale zero-valent iron (nZVI) assembled on graphene oxide (GO) (rGO-nZVI) composites were synthesized by reduction of GO and ferrous ions with potassium borohydride, for use in Cr(VI) removal from aqueous solution. The results showed that the two-dimensional structure of GO could provide a skeleton support for Fe0, thus overcoming the bottleneck of aggregation for nZVI. Also, rGO-nZVI would form a ferric-carbon micro-electrolysis system in Cr(VI)-contaminated aquifers, enhancing and accelerating electron transfer, exhibiting high rate and capacity for Cr(VI) removal. The optimum dosage of the applied rGO-nZVI was linearly correlated with the initial Cr(VI) concentration. Characterization of rGO-nZVI before and after reaction with Cr(VI) revealed the process of Cr(VI) removal: rGO-nZVI firstly transferred electrons from Fe0 cores via their Fe(II)/Fe(III) shells to the GO sheet; there, negatively charged Cr(VI) received electrons and changed into positively charged Cr(III), which was adsorbed by the negatively charged GO sheet, avoiding the capping and passivating of nZVI rGO-nZVI formed a good electrically conductive network, and thus had long-term electron releasing properties, which was important for groundwater remediation. Nanoscale zero-valent iron (nZVI) assembled on graphene oxide (GO) (rGO-nZVI) composites were synthesized by reduction of GO and ferrous ions with potassium borohydride, for use in Cr(VI) removal from aqueous solution. The results showed that the two-dimensional structure of GO could provide a skeleton support for Fe0, thus overcoming the bottleneck of aggregation for nZVI. Also, rGO-nZVI would form a ferric-carbon micro-electrolysis system in Cr(VI)-contaminated aquifers, enhancing and accelerating electron transfer, exhibiting high rate and capacity for Cr(VI) removal. The optimum dosage of the applied rGO-nZVI was linearly correlated with the initial Cr(VI) concentration. Characterization of rGO-nZVI before and after reaction with Cr(VI) revealed the process of Cr(VI) removal: rGO-nZVI firstly transferred electrons from Fe0 cores via their Fe(II)/Fe(III) shells to the GO sheet; there, negatively charged Cr(VI) received electrons and changed into positively charged Cr(III), which was adsorbed by the negatively charged GO sheet, avoiding the capping and passivating of nZVI rGO-nZVI formed a good electrically conductive network, and thus had long-term electron releasing properties, which was important for groundwater remediation.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2018年第11期96-106,共11页 环境科学学报(英文版)
基金 supported by the National Natural Science Foundation of China(Nos.41772244 and 41530636)
关键词 Reduced graphene oxide-nano zero value iron (rGO-nZVI) Micro-electrolysis Cr(VI) removal Groundwater remediation Reduced graphene oxide-nano zero value iron (rGO-nZVI) Micro-electrolysis Cr(VI) removal Groundwater remediation
  • 相关文献

同被引文献88

引证文献12

二级引证文献57

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部