基于在均质地层场地内进行的热响应试验,此文通过对地埋管热响应试验观测孔不同深度地温数据与稳态温度场理论分析特征对比,从时间和空间两方面总结了非稳态下均质岩体内竖直地埋管周围的热传导特征。分析发现:该次试验竖直地埋管排热过程中周围地层非稳态地温场的分布特征与根据公式求得的均质无限大介质中线热源排热形成的稳态地温场分布在空间分布形态上有一致性;持续排热工况下竖直地埋管的影响半径为一动态数值,与排热持续时间相关性较大。
Based on the thermal response test conducted in a homogeneous formation site, through analysis and comparasion of geothermal data and steady state temperature field at different, from the aspects of time and space, heat conduction characteristics of homogeneous rock mass surrounding the borehole tube under the unsteady state condition have been summarized. It is found that the distribution characteristics of the unsteady geothermal field of the surrounding strata in the vertical heat dissipation process of this ex periment are consistent with the steady state geothermal field distribution formed by the heat source heat removal of the homogeneous infinite medium obtained by the formula. The influence radius of the vertical buried pipe under continuous heat discharging conditions is a dynamic value, which is highly correlated with the duration of heat removal.
作者
孟甲
刘怀思
张茜
袁成军
仝路
贾琛
姜福红
MENG Jia;LIU Huaisi;ZHANG Qian;YUAN Chengjun;TONG Lu;JIA Chen;JIANG Fuhong(No.2 Geological Brigade of Shandong Exploration Bureau of Geology and Mineral Resources,Shandong J ining 272100,China;No.3 Hydrogeology and Engineering Geological Brigade of Shandong Exploration Bureau of Geology and Mineral Resources,Shandong Jining 272100,China;Lunan Geo engineering Investigation Institute,Shandong Jining 272100,China)
出处
《山东国土资源》
2018年第12期13-16,共4页
Shandong Land and Resources
基金
山东省国土资源厅
滕州市浅层地温能调查评价
鲁国土资函[2017]151号
关键词
地源热泵
竖直埋管
非稳态
影响半径
感应时间
Ground source heat pump
virtical buried pipe
unsteady state
influence radius
induction time