摘要 以某电站耐张绝缘子串爬电现象为背景,研究了污秽条件下影响绝缘子绝缘强度的因素。通过重新划分污区、采用新材料及新伞形,提高了爬电距离及污秽绝缘子耐受电压,提高了耐张绝缘子的绝缘强度,消除了爬电现象。 Based on the phenomenon of creepage of tension insulator strings in a power station, the factors affecting the insulation strength of theinsulators under contaminated conditions were studied. By re-dividing the contaminated areas, using new shed-type insulators with new materials, thecreepage distance and the withstand voltage of the insulators were improved, the insulation strength of the tension insulators was thus improved, andthe creepage phenomenon was eliminated.
作者 董小录 王夏洋 王思超 DONG Xiaolu;WANG Xiayang;WANG Sichao(Hejin Electric Power Generation Company of Shanxi Zhangze Power Co.,Ltd.,Hejin,Shanxi 043300,China)
出处 《山西电力》 2018年第5期43-46,共4页 Shanxi Electric Power
关键词 绝缘强度 爬电距离 污秽耐受电压 憎水性 insulation strength creepage distance contamination withstand voltage hydrophobicity