摘要
针对目前综采工作面进风侧发生火灾等通防灾变,工作面因很少具备局部反风条件而导致火灾蔓延带来巨大的损失的现状,介绍了由远程控制自动风门、远程控制自动调节风窗及风速传感器等组成的综采工作面远程控制局部反风系统。对该局部反风系统在神东补连塔煤矿12511综采工作面取得的效果进行评估,实践证明该局部反风系统安全可靠、经济高效。
In view of the current situation of fire and other disasters on the wind side of the fully mechanized working face causing great loss due to the lack of local anti-wind conditions, this paper introduces the remote control of local anti-wind system by remote control automatic wind door, remote control automatically adjusting wind window and wind speed sensor, etc. Evaluation of the effect of the local anti-wind system on 12511 full-mechanized working face of Shendong Bulianta Coal Mine is carried out. The practice proves that the local anti-wind system is safe, reliable and economical.