期刊文献+

500kV耐张塔内转角跳线串合成绝缘子舞动脱落原因分析 被引量:4

Cause Analysis of Galloping Shedding for Composite Insulators with Angle Jumper String in 500kV Tension Tower
下载PDF
导出
摘要 针对数起500kV耐张塔内转角跳线合成绝缘子舞动脱落的情况,结合合成绝缘子的特点、耐张塔内转角跳线的特殊性进行分析,发现耐张塔内转角跳线加装合成绝缘子的问题,提出防止耐张塔内转角跳线串舞动脱落的建议。 Aiming at several incidents of galloping shedding of composite insulators of angle jumper string in 500 kV tension tower, this paper analyzes the characteristics of composite insulators and the particularity of the angle jumper string in the tension tower and finds out the problems of adding composite insulators to the angle jumper string in the tension tower. And the paper also raises some suggestions to prevent the galloping shedding of the angle jumper string in the tension tower.
作者 葛雄 金哲 雷雨 王京波 李嗣 GE Xiong;JIN Zhe;LEI Yu;WANG Jingbo;LI Si(Maintenance Company,State Grid Hubei Electric Power Co.Ltd.,Wuhan Hubei 430050,China)
出处 《湖北电力》 2018年第3期19-21,共3页 Hubei Electric Power
基金 国网湖北省电力公司检修公司科技项目(项目编号:B1152017000500T60000001)
关键词 500 kV耐张塔 内转角跳线串 合成绝缘子 舞动脱落 500 kV tension tower inner corner jumper string composite insulators galloping shedding