针对数起500kV耐张塔内转角跳线合成绝缘子舞动脱落的情况,结合合成绝缘子的特点、耐张塔内转角跳线的特殊性进行分析,发现耐张塔内转角跳线加装合成绝缘子的问题,提出防止耐张塔内转角跳线串舞动脱落的建议。
Aiming at several incidents of galloping shedding of composite insulators of angle jumper string in 500 kV tension tower, this paper analyzes the characteristics of composite insulators and the particularity of the angle jumper string in the tension tower and finds out the problems of adding composite insulators to the angle jumper string in the tension tower. And the paper also raises some suggestions to prevent the galloping shedding of the angle jumper string in the tension tower.
作者
葛雄
金哲
雷雨
王京波
李嗣
GE Xiong;JIN Zhe;LEI Yu;WANG Jingbo;LI Si(Maintenance Company,State Grid Hubei Electric Power Co.Ltd.,Wuhan Hubei 430050,China)
出处
《湖北电力》
2018年第3期19-21,共3页
Hubei Electric Power
基金
国网湖北省电力公司检修公司科技项目(项目编号:B1152017000500T60000001)
关键词
500
kV耐张塔
内转角跳线串
合成绝缘子
舞动脱落
500 kV tension tower
inner corner jumper string
composite insulators
galloping shedding