摘要 某电厂600MW超临界机组屏式过热器爆管事故发生后,对其宏观特征、化学成分、金相组织和力学性能等方面进行了实验分析。根据实验结果,结合受热面结构特点及现场勘察情况,推测本次爆管失效原因是由于异物堵塞引起的短时过热。同时,针对爆管的堵塞提出了锅炉在制造、安装、运行、检修各阶段的防治措施。 After the appearance of the tube bursting accident of the platen superheater of 600 MW supercritical unit of a power plant, the experimental analysis for macroscopic characteristics, chemical composition, metallographic structure and mechanical properties, etc were carried out. According to the experimental results, combining with the structure characteristics of heating surface and the field survey situation, it is speculated that the failure of tube bursting is due to the short-term overheating caused by the foreign matter blockage. At the same time, aiming at the blockage of the tube bursting, the prevention and control measures of the boiler in the process of manufacturing, installation, operation and overhaul are put forward.
作者 李戈 朱海宝 陈卓婷 LI Ge;ZHU Haibao;CHEN Zhuoting(Department of Materials Technology,Huadian Electric Power Research Institute,Hangzhou 310030,China)
出处 《热加工工艺》 CSCD 北大核心 2018年第20期257-260,共4页 Hot Working Technology
关键词 超临界机组 屏式过热器 爆管 短时过热 异物堵塞 supereritical unit platen superheater tube bursting short-term overheating foreign matter blockage
  • 相关文献

参考文献2

二级参考文献3

  • 1林福生.我国发电设备测量材料和需要解决的几个问题[A].中国动力工程学会成立四十周年文集[C].北京:中国动力工程学会,2002.
  • 2ASME锅炉及压力容器委员会材料分委员会,中国《ASME规范产品》协作网(CACI).SA-210/SA-210M锅炉和过热器用无缝中碳钢管子.北京:中国石化出版社,2002.
  • 3国家质量技术监督局.GB/T 13298-1991金属显微组织检验方法[S],1991.