摘要 东南亚国家建筑方案多采用建筑内天井通风采光,本项目方案设计之初拟将空调室外机放置于内天井中。基于Airpak3. 0气流模拟软件,对内天井中的气流进行数值模拟,验证了在一定时间稳定之后,空调室外机的工作环境温度超过其允许的最高温度。同时通过对比3种不同工况下的模拟结果,得出方形内天井较长方形内天井散热更优的结论。通过试算得到本项目条件下满足使用要求的最小内天井尺寸,对于方案确定具有重要意义。 Inner courtyard is frequently adopted for ventilation and lighting in Southeast Asian Architectural Design. In this project, designers decided to place the outdoor air conditioner inside the inner courtyard, however the machine cooling would be dramatically influenced by the size of this courtyard. For this reason, relevant thermal simulation is necessary. Based on the airflow simulation result conducted by Airpak 3.0, this paper verified that the operating temperature of outdoor air conditioner after stabilized would be higher than its' allowable maximal temperature. Additionally, by comparing with simulation results' acquired under three different conditions, the conclusion that the cooling effect of inner courtyard in square shape on outdoor air conditioner is better than rectangle shape courtyard. The calculation process of gaining the minimal size of inner courtyard that can fulfil related requirement in this project is also shown, and this experiment result plays a role in the decision making process of architectaral design.
作者 宣晨晨 祝健 XUAN Chen-chen;ZHU Jian(Guangdong Bo Yi Architectural Design Institute Co.,Ltd.,Foshan 528311,Guangdong,China;Hefei University of Technology,Hefei 230009,China)
出处 《建筑节能》 CAS 2018年第11期11-14,共4页 BUILDING ENERGY EFFICIENCY
关键词 Airpak3.0 内天井 空调室外机 热环境模拟 最小尺寸 Airpak3. 0 inner courtyard outdoor air conditioner thermal environment simulation minimum size
  • 相关文献

参考文献1

二级参考文献6

  • 1袁凤东,由世俊,杨向劲.地铁侧式站台空调气流CFD模拟[J].西南交通大学学报,2005,40(3):303-307. 被引量:17
  • 2Zhu Yingxin, Xia Chunhai, Lin Borong. Discussing on methodology of applying building thermal simulation in conceptual design[C] // Proceedings of the 10th International Building Performance Simulation Association Conference and Exhibition. Beijing, 2007.
  • 3Bourgeois D, Reinhart C F. Differential time scale solutions for dynamic boundary conditions within whole-building energy simulation[C]//Proceedings of the 10th International Building Performance Simulation Association Conference and Exhibition. Beijing, 2007.
  • 4张也影.流体力学[M].北京:高等教育出版社,1999..
  • 5夏春海,朱颖心,林波荣.方案设计阶段建筑性能模拟方法综述[J].暖通空调,2007,37(12):32-40. 被引量:24
  • 6彭绪亚,李百战,陈启高,姚润明.低能耗建筑室内热环境质量评价[J].重庆建筑大学学报,1998,20(5):19-22. 被引量:1

共引文献7

同被引文献61

引证文献5

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部