像素闪耀算法在提高单源双能CT低单能量图像对肝内小转移瘤显示的价值

The value of the pixel shine algorithm in improving the display of small hepatocellular metastases in low single energy image with single-source dual-energy CT
下载PDF
导出
摘要 目的:探讨深度学习像素闪烁(Pixel shine,PS)(AlgoMedica,Inc,Sunnyvale,CA)算法提升单源双能CT平扫单能量图像显示肝内小转移瘤图像质量的价值,尤其提高低能量图像对病灶显示的价值。方法:回顾性搜集肝转移瘤的患者14例,共38个病灶。使用单源双能CT(GE Discovery HD 750,USA),行GSI扫描,对AW4.6工作站所得的平扫低单能量图像进行PS算法(A7模式)处理,得到PS前后平扫40~70 KeV单能量图像。由1名影像诊断医师在40~70 KeV单能量图像的同一层面(显示病灶的最大层面)、同一位置分别在肝转移瘤、正常肝实质勾画感兴趣区(ROI),测量并记录各ROI的CT值及SD值,计算PS前后各单能量图像肝转移瘤的SNR、肝转移瘤相对于正常肝实质的CNR以及PS后SNR和CNR较PS前增大的比率。采用Shapiro-Wilk正态分布检验检查数据正态性。比较PS前后40~70 KeV四组单能量图像中肝转移瘤和正常肝实质的CT值、肝转移瘤SNR及CNR,并且,将PS后40 KeV、50 KeV、60 KeV图像中的肝转移瘤SNR、CNR与PS前70 KeV图像相比较。其中符合正态分布的数据使用配对样本t检验比较其差异,余不符合正态分布则使用Wilcoxon符号秩和检验。采用非参数Friedman检验分别比较PS后40~70 KeV各单能量图像SNR和CNR增大比率的差异,若存在差异则采用Wilcoxon符号秩和检验进行两两比较。结果:PS前后40~70 KeV四组单能量图像中肝转移瘤、肝实质的CT值无统计学差异(P>0.05),而PS后40~70 KeV四组单能量图像中肝转移瘤的SNR、CNR均显著大于PS前(P均为0.000)。与PS前70 KeV图像中肝转移瘤SNR、CNR相比,PS后40 KeV图像的肝转移瘤SNR小于PS前70 KeV图像,而PS后50 KeV、60 KeV图像的肝转移瘤SNR以及PS后40 KeV、50 KeV、60 KeV图像的肝转移瘤CNR均明显大于PS前70 KeV图像。Friedman检验显示PS后40~70 KeV单能量图像肝转移瘤SNR和CNR较相应PS前图像SNR和CNR增大的比率之间具有统计学差异(P=0.000,P=0.000),其中40 KeV与50 KeV之间的SNR和CNR的增大比率无统计学差异(P=0.255,P=0.429),40 KeV和50 KeV单能量图像PS后SNR、CNR增大比率均显著大于60 KeV、70 KeV图像。结论:PS算法可以明显提高单源双能CT平扫单能量图像对显示肝内小转移瘤灶的图像质量,并且PS算法在低单能量图像中对病灶显示方面具有更好的效果。 Objective: To explore the value of pixel shine(PS) algorithm to improve the quality of single-energy image, es- pecially the low single-energy image by single-source dual-energy CT, and to improve the detection of small liver metastases. Methods: Fourteen patients, who underwent spectral CT imaging using spectrum imaging modality (GSI) were retrospectively enrolled with 38 lesions in this study. The PS algorithm (A7 mode) was applied to process the low single-energy images ob- tained from the AW4.6 workstation to obtain four groups of 40-70 KeV single energy images before and after calculation by PS. The ROIs were draw in the liver metastases and normal liver parenchyma respectively at the same location and on the same slice, showing the maximum area of the lesion, of 40-70 KeV single-energy images by a senior radiologist, then CT and SD values were measured and recorded. The SNRs of liver metastases, the CNRs of liver metastases relative to normal liver parenchyma and the ratios of SNRs and CNRs in images after calculation by PS relative to before were calculated. The Shapiro-Wilk normal distribution test was used to check the normality of data. The CT values of liver metastases and normal liver parenchyma, SNRs and CNRs of hepatic metastases were compared between four groups of 40-70 KeV single energy im- ages before and after calculation bv PS. then the SNRs and CNRs of hepatic metastases in 40 KeV. 50 KeV and 60 KeV im-ages processed by PS algorithm were compared with those in 70 KeV images. Paired samples t-test was used to compare the data that fit the normal distribution, and the Wilcoxon signed-rank test was used to compare the data that didn't conform to normal distribution. The nonparametric Friedman test was used to compare the differences of SNR and CNR increase ratios of 40-70 KeV single energy images processed by PS algorithm. If there was a difference, the Wilcoxon signed rank test was used for comparison. Results: There were no differences between the CT values of liver metastases and liver parenchyma in four groups of 40-70 KeV single energy images before and after calculation by PS (P〉0.05). The SNR and CNR of liver metastases in 40-70 KeV single energy images processed by PS algorithm were greater than those in images without PS calculation(all P= 0.000). Compared with SNRs and CNRs of hepatic metastases in 70 KeV PS images, the SNRs of hepatic metastases in 40 KeV images processed by PS was less than that in 70 KeV images without PS calculation, while the SNRs of hepatic metastases in 50 KeV and 60 KeV images processed by PS and the CNRs of liver metastases in 40 KeV, 50 KeV and 60 KeV images pro- cessed by PS were significantly greater than that in 70 KeV images without PS calculation. Conclusion: nificantly improve quality of single-energy images to show the intrahepatic metastasis lesion, and the PS low single energy image has better effect on the display of lesions. PS algorithm can sig- algorithm used in the
作者 徐明哲 刘爱连 刘义军 刘静红 潘聚东 XU Ming-zhe1, LIU Ai-lian1, LIU Yi-jun1, LIU Jing-hong1, PAN Ju-dong2(1. Department of Radiology, the First Affiliated Hospital of Dalian Medical University, Dalian Liaoning 116011, China; 2. Department of Radiology, University of California San Francisso, San Francisso 173304, Americ)
出处 《中国临床医学影像杂志》 CAS 2018年第11期782-787,共6页 Journal of China Clinic Medical Imaging
关键词 肝肿瘤 肿瘤转移 体层摄影术 螺旋计算机 Liver neoplasms Neoplasm metastasis Tomography spiral computed
  • 相关文献

参考文献9

二级参考文献97

  • 1Andreas Christe,Johannes Heverhagen,Christoph Ozdoba,Christian Weisstanner,Stefan Ulzheimer,Lukas Ebner.在最后三扫描仪代的 CT 剂量和图象质量[J].World Journal of Radiology,2013,5(11):421-429. 被引量:10
  • 2徐克,任克.布加综合征非创伤性影像学检查的应用与评价[J].中华医学杂志,2005,85(5):296-297. 被引量:15
  • 3K.Shimada,H.Isoda,Y.Hirokawa,S.Arizono,T.Shibata,K.Togashi,程悦.比较Gd-EOB-DTPA增强MRI与扩散加权成像对肝内小转移灶的检出[J].国际医学放射学杂志,2011(1). 被引量:6
  • 4Matsumoto K, Jinzaki M, Tanami Y, et al. Virtual monochromatic spectral imaging with fast kilovohage switching: improved image quality as compared with that obtained with conventional 120 kVp CT. Radiology, 2011 ,In press.
  • 5Lv P, Lin XZ, Li J, et al. Differentiation of small hepatic hemangioma from small hepatocellular carcinoma: recently introduced soectral CT method. Radioloav. 2011. In nress.
  • 6Lin XZ, Miao F, Li JY, et al. High-definition CT gemstone spectral imaging of the brain: initial results of selecting optimal monochromatic image for beam-hardening artifacts and image noise reduction. J Comput Assist Tomogr, 2011, 35:294-297.
  • 7Zhao LQ, He W, Li JY, et al. Improving image quality in portal venography with spectral CT imaging. Eur J Radiol, 2011, In press.
  • 8Feuerlein S, Roessl E, Proksa R, et al. Muhienergy photoncounting K-edge imaging: potential for improved luminal depiction in vascular imaging. Radiology, 2008, 249 : 1010-1016.
  • 9Pan D, Roessl E, Schlomka JP,et al. Computed Tomography in color: nanok-enhanced spectral CT molecular imaging. Angew Chem Int Ed Engl,2010, 49:9635-9639.
  • 10Cormode DP, Roessl E, Thran A, et al. Atherosclerotic plaque composition: analysis with multicolor CT and targeted gold nanoparticles. Radiology, 2010, 256:774-782.

共引文献438

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部