配电网供电可靠性是反映配电网运营及管理水平的重要指标之一。通过手拉手配电网线路进行合环转供是减少用户停电、提高供电可靠性的重要手段。为明确安全可靠的合环操作区间,文章从理论出发,在考虑了多种约束的基础上,提出了一种配电网合环操作安全校验方法,对分区运行背景下的成都城区配电网合环情况进行了研究,证明了目前成都电网还有进一步扩大合环操作范围,减少停电次数的潜力。
The reliability of distribution network is one of the important indicators reflecting the operation and management level of distribution network.Closing operation of distribution network with hand-in-hand structure is an important means to reduce power outages and improve power supply reliability.In order to define the safe and reliable loop-closing operation interval,this paper proposes a safety-constrained decision-making method for the closing operation of Chengdu distribution network considering security constraints.It is proved that the application range of closing operation of Chengdu distribution network can be further expanded to reduce the potential of power outage.
作者
苏小平
周维阳
胡启元
周锟
曾鹏
魏宏芬
邹经鑫
SU Xiaoping;ZHOU Weiyang;HU Qiyuan;ZHOU Kun;ZENG Peng;WEI Hongfen;ZOU Jingxin(State Grid Chengdu Power Supply Company,Chengdu 610041,China;State Key Laboratory of Power Transmission Equipment & System Security and New Technology,The Electrical Engineering College,Chongqing University,Chongqing 400044,China)
出处
《供用电》
2018年第12期29-35,共7页
Distribution & Utilization
基金
国网四川省电力公司群创科技项目(5219041 80003)~~
关键词
配电网
合环
分区运行
安全约束
distribution network
loop-closing
partition operation
safety-constraint