分析了新钢焦化厂2#干熄焦锅炉爆管的原因,通过稳定锅炉操作、加强锅炉加药操作和除盐水水质监督、定期维护干熄焦锅炉,可预防干熄焦锅炉爆管,保证干熄焦的稳定运行。
The cause of 2# CDQ boiler tube bursting in Coking Plant of Xinyu Iron & Steel is analyzed. Its preventive measures are also given, such as by stabilizing the boiler operation, improving chemical dosing,controlling demineralized water quality and periodically doing maintenance for the boiler,so that the CDQ unit can run in a stable manner.
作者
肖忠东
蒋忠平
Xiao Zhongdong;Jiang Zhongping(Xinyu Iron & Steel Group Co.,Ltd.,Xinyu 338001,China)
出处
《燃料与化工》
2018年第6期24-25,共2页
Fuel & Chemical Processes
关键词
干熄焦
锅炉爆管
除盐水水质
预防措施
CDQ
Boiler tube bursting
Demineralized water quality
Preventive measures