摘要
以某工厂金工车间(二层楼盖)在机器开动时楼盖振动明显,员工振感明显,结构局部出现损伤,并影响机床加工精度,振动问题突出为研究对象,经过现场的振动监测,后期处理分析并得出引起振动的原因。
Taking the vibration, which affects the processing accuracy of the machine tool, with evident floor vibration and the vibration feeling by staff, and damages in some parts of the structure in some metal workshop at some factory as the example, the paper analyzes the treatment in later periods by the vibration monitoring on the sites, and concludes the reasons for the vibration.
作者
秦文
Qin Wen(Shanxi Academy of Building Research,Taiyuan 030001,China)
出处
《山西建筑》
2018年第34期51-53,共3页
Shanxi Architecture
关键词
振动测试
结构响应
主频
振幅
vibration test
structural response
dominant frequency
amplitude