期刊文献+

水温对离心泵汽蚀影响的试验验证及测试系统的改进 被引量:5

Experimental Verification of the Influence of Water Temperature on the Cavitation of Centrifugal Pump and the Improvement of Cavitation test
下载PDF
导出
摘要 介绍了一种集离心泵泵性能试验和汽蚀试验自动化运行的测试系统,包括其设备构成与测试方法;并通过具体试验,测试在不同水温下,离心泵NPSHr的变化趋势;验证介质温度对离心泵汽蚀的影响;对离心泵及汽蚀测试系统进行改进,减少介质温度对离心泵汽蚀测试的影响,提高试验精度。 The set of test system of centrifugal pump performance test and cavitation test automation operation was introduced, including their equipments and testing methods;And through specific experiments,Changing trend of the NPSHr was tested under different water temperature;verify that the media temperature has an affect on the cavitation.The centrifugal pump performance test system was improved,reducing the influence of the medium temperature on centrifugal pump performance test.
出处 《流体机械》 CSCD 北大核心 2016年第1期11-13 70,70,共4页 Fluid Machinery
关键词 离心泵 汽蚀试验 NPSHr 测试系统 改进 centrifugal pump cavitation test NPSHr test system improvement