目的探讨可穿戴医疗设备用于生命体征监测记录的临床应用效果。方法采用自身对照的方式,以60例口腔颌面外科住院患者为对象,在6:00、10:00、14:00、18:00分别使用可穿戴医疗设备(实验法)和传统耳温枪及监护仪(传统法)监测体温、脉搏、血氧饱和度、血压,比较两种采集方式所得数据结果及操作耗时。结果各时点两种方法测量的体温、脉搏、血氧饱和度、血压比较,差异无统计学意义(均P> 0. 05);实验法在数据转录耗时和总耗时上显著短于传统法(均P <0. 01)。结论使用可穿戴医疗设备监测生命体征的准确性好,且能够显著提高护理效率。
Objective To explore the effects of wearable medical device on vital signs monitoring. Methods A self-control study was conducted on 60 patients in department of oral maxillofacial surgery,receiving either wearable medical device or ear thermometer combining Mindray MP9000 monitor for measurement of vital signs at 6: 00,10: 00,14: 00 and 18: 00. The measurement results and time required to measure were compared. Results There were no significant differences in vital signs measured by these two methods( P〉0. 05 for all),but data transcribing time and the total time were significantly shorter by using wearable medical device( P〈0. 01 for both). Conclusion The accuracy of wearable medical device for vital signs monitoring was acceptable and could improve work efficiency.