期刊文献+

国产ICP-MS性能测试关键技术解析 被引量:1

Domestic ICP-MS performance test key technical analysis
下载PDF
导出
摘要 国产电感耦合等离子体质谱仪Mars-9000是聚光科技(杭州)股份有限公司在进口仪器性能优势的基础上自主研发的新仪器。仪器的性能是表征质量的关键,目前该仪器已通过大量的性能测试。本文总结分析了Mars-9000性能指标测试的关键技术,包括灵敏度、氧化物离子产率、双电荷离子产率、短期稳定性、长期稳定性、检出限、丰度灵敏度、同位素丰度比测量精度的测试。为日后同类产品的研发、仪器性能把控提供参考。 Domestic inductively coupled plasma mass spectrometer Mars-9000 was developed on the basis of the performance advantages of imported equipment by Focused Photonics(Hangzhou), Inc. Mars-9000 has been through a lot of the performance test to indicate its quality. This study summarized key performance testing technology for Mars-9000, including sensitivity, oxide ion yield, doubly charged ions yield, short-term stability, long-term stability, detection limit, abundance sensitivity, isotope ratio measurements accuracy. These performance testing technology can be used as reference for the domestic ICP-MS development in future.
出处 《世界有色金属》 2016年第1期67-70,共4页 World Nonferrous Metals
基金 国家重大科学仪器设备开发专项(2011YQ060100)
关键词 Mars-9000 性能测试 关键技术 Mars-9000 performance testing technology
  • 相关文献

参考文献5

二级参考文献43

共引文献91

同被引文献10

引证文献1

二级引证文献4