期刊文献+

The Design of A Kind of Electrical Appartus Based on FPGA

The Design of A Kind of Electrical Appartus Based on FPGA
下载PDF
导出
摘要 This paper deisgns a new kind of electrical appartus which developed by programmable logic devices FPGA and produce 2Hz,100Hz sine and rectangular wave signals based on the direct digital frequency synthesis principle.By testing,the frequency of output signal is precise,the output waveforms are stable.Because of using FPGA,the Peripheral equipments are fewer,with design flexible,field programmable,easy debugged and small volume. This paper deisgns a new kind of electrical appartus which developed by programmable logic devices FPGA and produce 2Hz,100Hz sine and rectangular wave signals based on the direct digital frequency synthesis principle.By testing,the frequency of output signal is precise,the output waveforms are stable.Because of using FPGA,the Peripheral equipments are fewer,with design flexible,field programmable,easy debugged and small volume.
出处 《Journal of Measurement Science and Instrumentation》 CAS 2010年第S1期95-96,113,共3页 测试科学与仪器(英文版)
关键词 A ELECTRIC apparatus DDS FPGA A Electric apparatus DDS FPGA
  • 相关文献

参考文献8

二级参考文献15

  • 1秦爱粉,杨湘云.因特网成瘾及其发生机制研究的现状[J].中国健康教育,2004,20(9):851-852. 被引量:4
  • 2吴远斌.数字式接收机设计[J].现代雷达,1996,18(3):91-96. 被引量:8
  • 3Yong KS.Internet addiction:the emergence of a new clinical disorder[J].Cyber Psychol Behav,1996,1:237-244
  • 4Young KS.Internet addiction:symptoms,evaluation,and treatment.[M]// Vandecreek L,Jackson T,eds.Innovations in clinical practice:a source book[M].Sarasota,Fl:Professional Resource Press,1998,19-31
  • 5Davis RA.A congnitive-behavior model of pathological Internet use[J].Comput Human Behav,2001,17:187-195
  • 6Koepp MJ,Gunn RN,Lawrence AD,et al.Evidence for striatal dopamine release during a video game[J].Nature,1998,393:262-268
  • 7Han JS,Wang Q.Mobilization of specific neuropeptides by peripheral stimulation of identified frequencies[J].News Physiol Sci,1992,7:176-180
  • 8Han JS.Acupuncture:neuropeptides release produced by electrical stimulation of different frequencies[J].Trends neurosci,2003,26(3):17-22
  • 9Zhong Fei,Liuzhen Wu,Jisheng Han.Inhibitory effects of single-trial transcutaneous electrical nerve stimulation at 2 Hz on cue-induced heroin craving and cue-reactivity[J].Addict Biol,2006,11:184-189
  • 10刘波,胡建彰.用于FLEX10K系列器件配置的一种改进方案[J].电子技术应用,1999,25(2):66-67. 被引量:3

共引文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部