目的:对艾康公司心肌标志物三合一检测板进行临床应用评价;方法:设实验组和对照组,分别用中生公司肌钙蛋白I快速检测板、艾康公司心肌酶三合一检测板和传统心肌酶生化检测等三种方法对比,同时对阳性病例在不同发病时间检出符合率进行比较分析,同时对有关影响因素进行检测对比;结果:艾康公司心肌三合一检测板可同时检测肌钙蛋白、肌红蛋白和CKM三项指标,对AMI检出阳性率39.8%,阴性符合率100%,阳性符合率98.3%,均高于肌钙蛋白I金标检测法和心肌酶生化检测法,发病12小时内检出符合率心肌标志物三合一检测为94.9%,均高于其他二种方法;讨论:临床应用表明,心肌三合一金标检测板法操作简便,结果迅速准确,可对急性心肌梗塞(AMI)早期诊断提供重要依据,为目前诊断AMI提供了一种简便快速和准确实用的实验方法。
Objective:the research purpose of Yi Kang company evaluate clinical application of myocardial markers triad examination board; Methods: the experimental group and the control group, respectively with rapid detection of troponin I in company board, myocardial enzyme Yi Kang company triad test plate and the traditional myocardial enzymes and biochemical test three kinds of methods such as contrast, at the same time at different time to check out the coincidence rate of positive cases in comparative analysis, at the same time to test the relevant factors affecting the contrast; Results: myocardial triad Yi Kang company can simultaneously detect troponin test board, myoglobin and CKM three indicators, the detection of AMI were 39.8%, negative coincidence rate 100%, the positive coincidence rate of 98.3%, higher than the troponin I jinbiao test and myocardial enzymes and biochemical assay, within 12 hours of myocardial markers triad detection detection coincidence rate was 94.9%, were higher than the other two methods; Discussion: clinical application showed that myocardial triad jinbiao detection plate method is simple, rapid and accurate results, but for acute myocardial infarction(AMI) provide important basis for early diagnosis, for the diagnosis of AMI provides a simple and rapid and accurate and practical method.
出处
《长沙医学院学报》
2014年第4期37-39,共3页
Journal of Changsha Medical University
关键词
急性心肌梗塞
心肌标志物
检测
应用评价
acute myocardial infarction(mi)
Myocardial markers
Detection
Application of evaluation