期刊文献+

能谱CT对肺内占位良恶性鉴别及诊断价值 被引量:5

Identification and Diagnostic Value of Energy Spectrum CT for Benign and Malignant Pulmonary Lesions
下载PDF
导出
摘要 目的探讨能谱CT对肺内占位良恶性的鉴别及诊断价值。方法选择我院2015年3月至2017年10月经影像学检查(X线、CT)发现肺内占位的57例患者作为研究对象,根据病理检查结果将其分为良性占位组(n=21)和恶性占位组(n=36)。两组患者均实施能谱CT成像技术,并对图像进行分析处理,对比两组动、静脉期40-80keV隔间单能量CT值,动脉期40-70keV期间能谱斜率,动、静脉期碘和水基值及差值。结果动、静脉期40-80keV隔间单能量CT值及动脉期40-70keV期间能谱斜率,良性占位组均低于恶性占位组,差异有统计学意义(P<0.05)。动、静脉期碘基值及差值,良性占位均低于恶性占位,差异有统计学意义(P<0.05);动、静脉期水基值及差值,良性占位均高于恶性占位,差异有统计学意义(P<0.05)。结论肺内占位良恶性在能谱CT表现上存在一定差异,其诊断结果对临床诊断具有一定参考价值。 Objective To explore the identification and diagnostic value of energy spectrum CT for benign and malignant lung lesions. Methods A total of 57 patients with pulmonary lesion examined by X-ray and chest CT from March 2015 to October 2017 were selected for the study. According to the pathological examination results, the patients were divided into benign lesion group(n=21) and malignant lesion group(n=36). The two groups were given energy spectrum CT imaging technique, and the images were analyzed and processed. The single-energy CT values of 40-80 keV compartments in arterial and venous phases, and the energy spectrum slope of 40-70 keV compartments in arterial phase, iodine base value and water base value and difference in arterial and venous phases were compared between the two groups. Results The single-energy CT values of 40-80 keV compartments in arterial and venous phases were lower in benign lesion group than those in malignant lesion group(P<0.05). There was a statistically significant difference in the energy spectrum slope of 40-70 keV compartments in arterial phase(P<0.05). The iodine base value and difference in arterial and venous phases were lower in benign lesion group than those in malignant lesion group(P<0.05). The water base value and difference in arterial and venous phases were higher in benign lesion group than those in malignant lesion group(P<0.05). Conclusion There are some differences in the energy spectrum CT findings of benign and malignant lung lesions. CT diagnostic results have certain reference value for clinical diagnosis.
作者 姚鹏鹏 李润涛 YAO Peng-peng;LI Run-tao(Zhengzhou Central Hospital,Zhengzhou 450003,Henan Province,China)
出处 《中国CT和MRI杂志》 2019年第4期45-47,153,共4页 Chinese Journal of CT and MRI
关键词 能谱CT 肺部肿瘤 诊断价值 Energy Spectrum CT Imaging Technique Benign and Malignant Lung Tumors Diagnostic Value
  • 相关文献

参考文献11

二级参考文献94

  • 1白荣杰,刘福全,申宝忠,王丹,韩铭钧,吴振华.孤立性肺结节多层螺旋CT灌注成像与血管生成的相关性研究[J].中华放射学杂志,2006,40(4):383-388. 被引量:38
  • 2陈明,陈景武.对应分析方法及其在临床上的应用[J].数理医药学杂志,2007,20(2):132-134. 被引量:14
  • 3刘大亮,马大庆,陈广.CT的分叶征表现在肺内孤立结节影像诊断中的价值[J].中华放射学杂志,2007,41(5):487-489. 被引量:57
  • 4丁毅,张镭,钱晓军,等.64层螺旋CT灌注成像在孤立性肺结鉴别诊断中的应用[J].中国医学影像技术,2007,23(2):214-218.
  • 5Dogan H, de Roos A, Geleijins J, et ah The role of computed tomography in the diagnosis of acute and chronic pulmonary em bolism[J]. Diagn Interv Radiol,2015,21(4) : 307- 316.
  • 6Newhouse J H, RoyChoudhury A. Quantitating contrast medium induced nephropathy: controlling the controls [J]. Radiology.2013,267(1) :4-8.
  • 7Katzberg RW,Barrett BJ. Risk of iodinated contrast material induced nephropathy with intravenous administration[J]. Radiol- ogy,2007,243(3) :622-628.
  • 8Matsuoka S, Hunsaker AR, Gill RR, et al. Vascular enhancement and image quality of MDCT pulmonary angiography in 400 cases: comparison of standard and low kilovoltage settings[J]. AJR, 2009,192(6) : 1651-1656.
  • 9Cheng J,Yin Y,Wu H, et al. Optimal monochromatic energy lew els in spectral CT pulmonary angiography for the evaluation of pulmonary embolism[J]. PLoS One, 2013,8 (7) : e63140.
  • 10Singh T,Lam KV,Murray C. Low volume contrast CTPA in pa- tients with renal dysfunction[J]. J Med Imaging Radiat Oncol, 2011,55(2), 143-148.

共引文献280

同被引文献48

引证文献5

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部