摘要
介绍了6000m3/h空分塔冷箱内泄漏的故障经过,分析了冷箱内泄漏原因,简述了处理措施,最后对空分安装、设计提出了建议。
The trouble occurrence of internal leakage of ASU expander cold chambers are described.The cause of internal leakage of expander cold chambers.The solutions are outlined.Finally the paper offers a suggestion on the project design and installation.
出处
《气体分离》
2011年第3期37-38,共2页
Gas Separation
关键词
大型空分设备
泄漏
原因分析
处理
Large-scale air separation unit
leakage
Cause analysis
Solution