期刊文献+

波幅和不规则参数的非线性组合——SIIR指数用于运动单位电位的分类

The SIIR index-A non-linear combination of waveform size and irregularity parameters for classification of motor unit potentials
下载PDF
导出
摘要 Objective: In clinical electromyography, motor unit potential(MUP) size is use d to indicate the myo-or neurogenic origin of the pathological process, whereas the irregularity of MUP shape is considered not useful in this respect. The aim of the present study was to find a method to improve classification of MUPs usi ng a combined analysis of the size and irregularity of the potential. Methods: T he records with at least 20%of irregular potentials from 14 healthy subjects an d 34 patients were analysed. Principal Component Analysis (PCA) was applied in t he analysis of data to find a linear function combining the size and the irregul arity of a MUP. Results: The linear combination of size and irregularity measure s, i.e. size index (SI) and irregularity coefficient (IR) obtained using Princip al Component Analysis (PCA) did not increase the discriminating ability incompar ison to SI.We have defined a non-linear function of the SI and IR called SIIR, which modifies SI values for irregular potentials only. Its discriminating abili ty is higher than that of SI. Conclusions: By combined assessment of the size of a MUP and its irregularity, the differentiation between neurogenic and myopathi c potentials could be considerably improved. Significance:The proposed coefficie nt SIIR seems to be more discriminating than others presently used. When applied in clinical studies it may be useful in the evaluation of confusing,atypical mo tor unit potentials. Objective: In clinical electromyography, motor unit potential(MUP) size is use d to indicate the myo-or neurogenic origin of the pathological process, whereas the irregularity of MUP shape is considered not useful in this respect. The aim of the present study was to find a method to improve classification of MUPs usi ng a combined analysis of the size and irregularity of the potential. Methods: T he records with at least 20%of irregular potentials from 14 healthy subjects an d 34 patients were analysed. Principal Component Analysis (PCA) was applied in t he analysis of data to find a linear function combining the size and the irregul arity of a MUP. Results: The linear combination of size and irregularity measure s, i.e. size index (SI) and irregularity coefficient (IR) obtained using Princip al Component Analysis (PCA) did not increase the discriminating ability incompar ison to SI.We have defined a non-linear function of the SI and IR called SIIR, which modifies SI values for irregular potentials only. Its discriminating abili ty is higher than that of SI. Conclusions: By combined assessment of the size of a MUP and its irregularity, the differentiation between neurogenic and myopathi c potentials could be considerably improved. Significance:The proposed coefficie nt SIIR seems to be more discriminating than others presently used. When applied in clinical studies it may be useful in the evaluation of confusing,atypical mo tor unit potentials.
机构地区 Bionics Department
出处 《世界核心医学期刊文摘(神经病学分册)》 2005年第8期34-34,共1页 Digest of the World Core Medical Journals:Clinical Neurology
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部