期刊文献+

穿透性角膜移植术后15年角膜内皮和术后的变化

Corneal endothelium and postoperative outcomes 15 years after penetrating keratoplasty
下载PDF
导出
摘要 Purpose: To determine changes in the central endothelium and thickness of grafted corneas and the cumulative probability of developing glaucoma, of graft rejection, and of graft failure 15 years after penetrating keratoplasty. Design: Longitudinal cohort study of 500 consecutive penetrating keratoplasties by one surgeon. Methods: Regrafted eyes, fellow eyes of bilateral cases, and patients not granting research authorization were excluded, leaving 388 grafts for analysis. At intervals after surgery, we photographed the endothelium and measured corneal thickness using specular microscopy. The presence of glaucoma, graft rejection, and graft failure were recorded. Results: The 67 patients examined at 15 years represented 30% of the available clear grafts. Endothelial cell loss from preoperative donor levels was 71± 12% (mean± standard deviation, n=67), endothelial cell density was 872± 348 cells/mm2, and corneal thickness was 0.59± 0.06 mm. Endothelial cell density was unchanged between 10 and 15 years, whereas corneal thickness increased (P=.001, n=55). The mean annual rate of endothelial cell loss from 10 to 15 years after surgery was 0.2± 5.7% (n=54). The cumulative probability of developing glaucoma, graft rejection, or graft failure was 20% , 23% , and 28% , respectively, and 6 of the 8 graft failures after 10 years resulted from late endothelial failure. Conclusions: From 10 to 15 years after penetrating keratoplasty, the annual rate of endothelial cell loss was similar to that of normal corneas, corneal thickness increased, and late endothelial failure was the major cause of graft failure. Purpose: To determine changes in the central endothelium and thickness of grafted corneas and the cumulative probability of developing glaucoma, of graft rejection, and of graft failure 15 years after penetrating keratoplasty. Design: Longitudinal cohort study of 500 consecutive penetrating keratoplasties by one surgeon. Methods: Regrafted eyes, fellow eyes of bilateral cases, and patients not granting research authorization were excluded, leaving 388 grafts for analysis. At intervals after surgery, we photographed the endothelium and measured corneal thickness using specular microscopy. The presence of glaucoma, graft rejection, and graft failure were recorded. Results: The 67 patients examined at 15 years represented 30% of the available clear grafts. Endothelial cell loss from preoperative donor levels was 71± 12% (mean± standard deviation, n=67), endothelial cell density was 872± 348 cells/mm2, and corneal thickness was 0.59± 0.06 mm. Endothelial cell density was unchanged between 10 and 15 years, whereas corneal thickness increased (P=.001, n=55). The mean annual rate of endothelial cell loss from 10 to 15 years after surgery was 0.2± 5.7% (n=54). The cumulative probability of developing glaucoma, graft rejection, or graft failure was 20% , 23% , and 28% , respectively, and 6 of the 8 graft failures after 10 years resulted from late endothelial failure. Conclusions: From 10 to 15 years after penetrating keratoplasty, the annual rate of endothelial cell loss was similar to that of normal corneas, corneal thickness increased, and late endothelial failure was the major cause of graft failure.
机构地区 Bourne
出处 《世界核心医学期刊文摘(眼科学分册)》 2005年第7期12-13,共2页 Digest of the World Core Medical Journals:Ophthalmology
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部