期刊文献+

获取带有活性内皮细胞的角膜后弹力层以行选择性角膜移植术的方法

A technique to harvest Descemet' s membra- ne with viable endothelial cells for selective transplantation
下载PDF
导出
摘要 Purpose: To describe a surgical technique using an artificial anterior chamber to facilitate harvest of Descemet’ s membrane (DM) and endothelium for corneal endothelial cell transplantation. Design: Laboratory investigation. Methods: Corneoscleral buttons of seven human donor eyesweremounted endothelial side up on an artificial anterior chamber. Keeping the endothelial side with its usual concavity, a manual trephination was made on the posterior surface with a 9.0- mm trephine, inside the Schwalbe line and just past the DM in depth. The chamber was filled with air, causing the endothelial side of the donor cornea to assume a convex configuration. The DM along with its endothelium was separated from the posterior stroma using a blunt cyclodialysis spatula. Drops of trypan blue 0.3% and alizarin red S 0.2% (n=6) were applied. The stained DMs were examined under a light microscope and photographed to calculate the percentage of endothelial cell damage. Histology was done on the unstained cornea. Results: The DM carrying endothelium was successfully removed from the posterior stroma in all seven eyes. Although the DM appears to be very friable, all samples were removed in toto without rupture. Vital staining showed amean endothelial cell loss of 8.46% (standard deviation (SD) 6.9). Direct light microscopy demonstrated the preservation of endothelial cell morphology. Conclusions: This technique appears to be a safe and straight for wardmethod to harvest DM for endothelial cell transplantation. Further studies are underway to determine the optimal method of insertion of the obtained healthy DM with endothelial cells through small corneal incisions. Purpose: To describe a surgical technique using an artificial anterior chamber to facilitate harvest of Descemet' s membrane (DM) and endothelium for corneal endothelial cell transplantation. Design: Laboratory investigation. Methods: Corneoscleral buttons of seven human donor eyesweremounted endothelial side up on an artificial anterior chamber. Keeping the endothelial side with its usual concavity, a manual trephination was made on the posterior surface with a 9.0- mm trephine, inside the Schwalbe line and just past the DM in depth. The chamber was filled with air, causing the endothelial side of the donor cornea to assume a convex configuration. The DM along with its endothelium was separated from the posterior stroma using a blunt cyclodialysis spatula. Drops of trypan blue 0.3% and alizarin red S 0.2% (n=6) were applied. The stained DMs were examined under a light microscope and photographed to calculate the percentage of endothelial cell damage. Histology was done on the unstained cornea. Results: The DM carrying endothelium was successfully removed from the posterior stroma in all seven eyes. Although the DM appears to be very friable, all samples were removed in toto without rupture. Vital staining showed amean endothelial cell loss of 8.46% (standard deviation (SD) 6.9). Direct light microscopy demonstrated the preservation of endothelial cell morphology. Conclusions: This technique appears to be a safe and straight for wardmethod to harvest DM for endothelial cell transplantation. Further studies are underway to determine the optimal method of insertion of the obtained healthy DM with endothelial cells through small corneal incisions.
出处 《世界核心医学期刊文摘(眼科学分册)》 2005年第7期13-14,共2页 Digest of the World Core Medical Journals:Ophthalmology
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部