期刊文献+

在经皮球囊二尖瓣成形术中非侵入性评估二尖瓣面积:实时3D超声心动图的作用

Non-invasive assessment of mitral valve area during percutaneous balloon mitral valvuloplasty: Role of realtime 3D echocardiography
下载PDF
导出
摘要 In the last decade, multiple studies depicted discrepancies between mitral valvular orifice area(MVA) measurements obtained with the pressure half-time(PHT) method and invasive methods during the immediate post-percutaneous mitral valvuloplasty(PMV) period. Our aim was to assess the accuracy of Real-Time 3D echo(RT3D) to measure the MVA in the immediate post-PMV period. The invasively determined MVA was used as the gold standard. We studied 29 patients with rheumatic mitral stenosis from two centres(27 women; mean age 48.2±11.3 years), all of which had underwent PMV. MVA was calculated before and after PMV using the PHT method, 2D echo planime try, RT3D echo planimetry and invasive determination (Gorlin’s method). The RT3D MVA assessment showed a better agreement with the invasively derived MVA before and in the immediate post-PMV period (Bland-Altman analysis: Average difference between both methods and limits of agreement: 0.01(-0.31 to 0.33) cm2 and -0.12(-0.71 to 0.47) cm2) before and immediately after the PMV, respectively. RT3D is a feasible and accurate technique for measuring MVA in patients with RMVS. It has the best agreement with the invasively determined MVA, particularly in the immediate post-PMV period. In the last decade, multiple studies depicted discrepancies between mitral valvular orifice area(MVA) measurements obtained with the pressure half-time(PHT) method and invasive methods during the immediate post-percutaneous mitral valvuloplasty(PMV) period. Our aim was to assess the accuracy of Real-Time 3D echo(RT3D) to measure the MVA in the immediate post-PMV period. The invasively determined MVA was used as the gold standard. We studied 29 patients with rheumatic mitral stenosis from two centres(27 women; mean age 48.2±11.3 years), all of which had underwent PMV. MVA was calculated before and after PMV using the PHT method, 2D echo planime try, RT3D echo planimetry and invasive determination (Gorlin's method). The RT3D MVA assessment showed a better agreement with the invasively derived MVA before and in the immediate post-PMV period (Bland-Altman analysis: Average difference between both methods and limits of agreement: 0.01(-0.31 to 0.33) cm2 and -0.12(-0.71 to 0.47) cm2) before and immediately after the PMV, respectively. RT3D is a feasible and accurate technique for measuring MVA in patients with RMVS. It has the best agreement with the invasively determined MVA, particularly in the immediate post-PMV period.
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部