期刊文献+

冠状动脉旁路移植术中用于吻合远端冠状动脉的一种新型机械吻合器:随机对照研究

A new mechanical connector for distal coronary artery anastomoses in coronary artery bypass grafting: A randomized, controlled study
下载PDF
导出
摘要 A new mechanical anastomotic device was evaluated, aiming at its future use in minimally invasive techniques or limited access surgery in patients undergoing coronary artery bypass grafting. Between April and December 2002, a total of 60 patients scheduled for elective multivessel bypass grafting were randomly assigned. One vein graftcoronary artery anastomosis per patient was either performed with the St Jude Medical ATG coronary connector system(n=30;St Jude Medical Inc, St Paul, Minn)or hand sewn(n=30). Selective coronary angiography or coronary magnetic resonance imaging of the studied graft and vessel was included in the 6-month follow-up. Twenty-eight of the connectors were successfully implanted. Two patients were excluded from the study because of conversion to hand-sewn anastomoses. Six connector-made anastomoses were bleeding at the anastomotic site. At the time of follow-up(190 postoperative days), all control anastomoses and grafts were patent, whereas 26%of the connector anastomoses were occluded. One graft in each group was patent but with stenosis. The St Jude Medical ATG coronary connector system for distal anastomoses represents a new concept for sutureless anastomoses in cardiac surgery. This randomized, controlled study shows lower graft patency for anastomoses performed with the connector than for hand-sewn control anastomoses. It illustrates the importance of controlled studies when evaluating new technical equipment in medicine. A new mechanical anastomotic device was evaluated, aiming at its future use in minimally invasive techniques or limited access surgery in patients undergoing coronary artery bypass grafting. Between April and December 2002, a total of 60 patients scheduled for elective multivessel bypass grafting were randomly assigned. One vein graftcoronary artery anastomosis per patient was either performed with the St Jude Medical ATG coronary connector system(n=30;St Jude Medical Inc, St Paul, Minn)or hand sewn(n=30). Selective coronary angiography or coronary magnetic resonance imaging of the studied graft and vessel was included in the 6-month follow-up. Twenty-eight of the connectors were successfully implanted. Two patients were excluded from the study because of conversion to hand-sewn anastomoses. Six connector-made anastomoses were bleeding at the anastomotic site. At the time of follow-up(190 postoperative days), all control anastomoses and grafts were patent, whereas 26%of the connector anastomoses were occluded. One graft in each group was patent but with stenosis. The St Jude Medical ATG coronary connector system for distal anastomoses represents a new concept for sutureless anastomoses in cardiac surgery. This randomized, controlled study shows lower graft patency for anastomoses performed with the connector than for hand-sewn control anastomoses. It illustrates the importance of controlled studies when evaluating new technical equipment in medicine.
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部