晚期心衰长期持续轴流泵辅助的可行性研究 被引量:1

Advanced heart failure: Feasibility study of long-term continuous axial flow pump support
下载PDF
导出
摘要 A lack of donor hearts has stimulated interest in using blood pumps to treat severe heart failure. We tested the hypothesis that a new continuous flow circulatory assist device could be employed safely to relieve symptoms of heart failure and evaluated the potential to prolong life. Methods and results: An intracardiac axial flow pump was implanted in 17 heart failure patients[idiopathic dilated(12), ischaemic(4), or amyloid cardiomyopathy(1)]. All were deemed ineligible for transplantation. Implantation of the device was by left thoracotomy(15) or median sternotomy(2). Power delivery was by a skull-mounted titanium pedestal. All patients survived surgery. None needed right ventricular support. There were three hospital deaths, two early from subdural haematoma and aortic thrombosis, one late after switching to transplantation. A total of 14 patients left hospital with a cumulative support-time of 15.9 years(median: 293 days, interquartile range: 286 days, 1- 44 months). Actuarial 1- , 2- , and 3- year survivals were 56, 47, and 24% , respectively. There was no pump failure. Quality of life scores improved. Two superficial pedestal infections were successfully treated. Four patients had cerebral thrombo-embolism: two early events attributed to inadequate anticoagulation and two late with near-complete resolution. An improved anticoagulant regime addressed this problem. Late death occurred in five patients from battery disconnection, subdural haematoma, bowel ischaemia, respiratory failure, and after cardiac transplantation. Conclusion: Continuous flow blood pumps provided symptomatic relief of severe heart failure with high quality of life. Event-free survival reached 4 years. Analysis of adverse events led to improved management strategies. There is potential for wide-spread use of blood pumps in the community. A controlled trial is required. A lack of donor hearts has stimulated interest in using blood pumps to treat severe heart failure. We tested the hypothesis that a new continuous flow circulatory assist device could be employed safely to relieve symptoms of heart failure and evaluated the potential to prolong life. Methods and results: An intracardiac axial flow pump was implanted in 17 heart failure patients[idiopathic dilated(12), ischaemic(4), or amyloid cardiomyopathy(1)]. All were deemed ineligible for transplantation. Implantation of the device was by left thoracotomy(15) or median sternotomy(2). Power delivery was by a skull-mounted titanium pedestal. All patients survived surgery. None needed right ventricular support. There were three hospital deaths, two early from subdural haematoma and aortic thrombosis, one late after switching to transplantation. A total of 14 patients left hospital with a cumulative support-time of 15.9 years(median: 293 days, interquartile range: 286 days, 1- 44 months). Actuarial 1- , 2- , and 3- year survivals were 56, 47, and 24% , respectively. There was no pump failure. Quality of life scores improved. Two superficial pedestal infections were successfully treated. Four patients had cerebral thrombo-embolism: two early events attributed to inadequate anticoagulation and two late with near-complete resolution. An improved anticoagulant regime addressed this problem. Late death occurred in five patients from battery disconnection, subdural haematoma, bowel ischaemia, respiratory failure, and after cardiac transplantation. Conclusion: Continuous flow blood pumps provided symptomatic relief of severe heart failure with high quality of life. Event-free survival reached 4 years. Analysis of adverse events led to improved management strategies. There is potential for wide-spread use of blood pumps in the community. A controlled trial is required.
  • 相关文献

同被引文献14

  • 1钱坤喜,李洪.叶轮血泵及其体外模拟试验[J].江苏大学学报(自然科学版),2004,25(6):521-524. 被引量:8
  • 2李小鹰.慢性心力衰竭的治疗:从治疗指南到临床实践[J].中华内科杂志,2005,44(7):484-485. 被引量:37
  • 3MEYER A, SLAUGHTER M. The total artificial heart [J]. Panminerva Med, 2011, 53(3): 141-154.
  • 4SLAUGHTER M S, BOSTIC R, TONG K, et al. Temporal changes in hospital costs for left ventricular assist device implantation [ J].Journal of Cardiac Surgery, 2011, 25 (6) : 535-541.
  • 5BOILSON B A, RAICHLIN E, PARK S J, et al. Device therapy and cardiac transplantation for end-stage heart failure[ J]. Curt Probl Cardiol, 2010, 35 ( 1 ) : 8-64.
  • 6BIRKS E J. Left ventricular assist devices [ J]. Heart, 2010, 96(1) : 63-71.
  • 7MENON A K. Current success and risks of mechanichal circulatory support [ J ]. Anasthesiol Intensivmed Notfallmed Schmerzther, 2011, 46 ( 6 ) : 434-441, quiz 442.
  • 8ASTMF1841-97(2013) Standard practice for assessment of hemolysis in continuous flow blood pumps [ EB/OL]. [2013-04-15 ]. http: // www. astm. org/Standards/ F1841. htm.
  • 9BOCK E, UEBELHART B, ANDRADE A, et al. Implantable centrifugal blood pump with dual impeller and double pivot bearing system: electromechanical actuator, prototyping and anatomical studies[ J]. Artificial Organs, 2011, 35(5) : 437-442.
  • 10ANDRADE A, BISCEGLI J, SOUZA J, et al. Flow visualization studies to improve the spiral pump design [J]. Artificial Organs, 21(7): 680-685.

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部