文中就茂名乙烯装置裂解气压缩机C-300于1999年大修改扩建后,在近33个月高负荷运行中暴露出压缩机一段吸入压力超高、机组转速无法提升等问题进行了分析,进而提出解决这些问题的措施并予以实施,以确保C-300机组安全及装置长、满、优运行。
During the 33 months' high capacity running, cracked gas gradually appeared some problems that the first suction pressure is higher than design value , the speed can t be lifted, etc. Aiming at these problems, the article analyzes the causes, then brings forward some countermeasures and puts into practice, so as to ensure the plant can run safely and steadily.