本文介绍了发电机转子电气部分的结构及绝缘损坏的危害,剖析了机组转子绝缘安装缺陷的成因,并针对各种处理方法的利弊进行分析,在此基础上就如何运用固定螺栓包扎绝缘的方法解决设计和安装工艺上存在的弊端进行了详细介绍。
This paper introduced the structure of generator rotor electrical parts and insulation damage, harm, analyzed the causes of generator insulation defect, and analyze the pros and cons of various treatment methods, based on how to use this method of fi xing bolt cover the insulation design and detailing the shortcomings of the installation process.
出处
《水电自动化与大坝监测》
2015年第3期11-15,共5页
HYDROPOWER AUTOMATION AND DAM MONITORING
关键词
转子绝缘
安装缺陷
固定螺栓包扎绝缘法
探索与应用
Rotor insulation
Installation defect
Fixing bolt cover the insulation
Method exploration and application